Long Term Event History; Rapid Resume Logic - Viper 330V Installation Manual

Car security
Hide thumbs Also See for 330V:
Table of Contents

Advertisement

long term event history

The control module will store the last 2 triggers in memory that are not erased when
the ignition is turned on. This can be helpful for trouble shooting false alarm reports.
To access the event history use the following procedure.
1. Turn the ignition switch off and press and hold the Valet
button.
®
2. While holding the Valet
button turn the ignition On.
®
3. Release the Valet
button.
®
4. Within 5-seconds, press and release the Valet
button.
®
The LED will flash in groups indicating the last two zones reported triggered. For
example, if zone 2 and 3 were the last two zones to be triggered, the LED will flash
two times followed by a pause and then flash three times followed by a pause.
N N O O T T E E : : The Warn Away
response does not report on the LED.
®
The Long Term Event History will exit if the ignition is turned off or there is no activity
for 60-seconds.

rapid resume logic

The current state of the alarm will be stored in non-volatile memory. If power is lost
and then reconnected, the system will recall the stored state from memory (arm, dis-
arm, and Valet
mode).
®