Vogelzang International DEFENDER TR001B Owner's Manual

Vogelzang International DEFENDER TR001B Owner's Manual

High efficiency air-tight woodstove
Hide thumbs Also See for DEFENDER TR001B:

Advertisement

DEFENDER
AIR-TIGHT WOODSTOVE
Model TR 001B Owners Manual
Le manuel de langue français est disponible à www.vogelzang.com
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING
THIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
REFER TO MARKINGS ON STOVE LABELS FOR
ADDITIONAL INFORMATION.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS
ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
TR001B | 20120125.0
HIGH EFFICIENCY
EPA Certified (4.22 grams/hr)
(Save These Instructions)
French language manual is available at www.vogelzang.com
www.vogelzang.com
This stove meets test standards:
US: UL 1482-2010 & CDN: ULC-S627-00
NOTE: IT IS RECOMMENDED INSTALLATION
BE COMPLETED BY A QUALIFIED HEATING
EQUIPMENT INSTALLER!
DO NOT INSTALL IN A MOBILE HOME.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
Report No. 235-S-01c-2
DEFENDER™ | Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DEFENDER TR001B and is the answer not in the manual?

Questions and answers

Summary of Contents for Vogelzang International DEFENDER TR001B

  • Page 1 SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA. Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com...
  • Page 2: Safety Precautions

    DO NOT CONNECT THIS UNIT TO A CHIMNEY tested with the use of grates, andirons or other means FLUE SERVING ANOTHER APPLIANCE. of elevating the fire and must not be used. Vogelzang International Corp. Page 2 | DEFENDER™ TR001B | 20120125.0...
  • Page 3 SAFETY INSTRUCTIONS continued… 18. The special paints used on your stove may give TION WITH ANY AIR DISTRIBUTION DUCT WORK UNLESS SPECIFICALLY APPROVED FOR SUCH off some smoke and an odor while they are cur- ing during the first 12 to 15 fires. Additional smoke INSTALLATIONS.
  • Page 4: Table Of Contents

    FLOOR PROTECTOR CALCULATIONS ............23 NOTE: A PROFESSIONAL, LICENSED HEAT- ING AND COOLING CONTRACTOR MUST BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF THIS SOLID FUEL BURNING APPLIANCE. Vogelzang International Corp. Page 4 | DEFENDER™ TR001B | 20120125.0...
  • Page 5: Tools And Materials Required For Installation

    ASSEMBLY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS AND MATERIALS REQUIRED FOR INSTALLATION or equivalent) tools ing.
  • Page 6: Locating The Stove

    UL 1482-2006 FLOOR FLOOR 16"/40.6cm min. 18"/46.8cm min. PROTECTOR PROTECTOR 15"/38.1cm 15"/38.1cm 23"/54.5cm 6"/15.2cm min. 23"/54.5cm 8"/20.3cm min. min. min. Fig. 6 – Top View Minimum Clearance Dimensions from Combustible Surfaces Vogelzang International Corp. Page 6 | DEFENDER™ TR001B | 20120125.0...
  • Page 7 LOCATING STOVE your local building codes or fire protection C A U T I O N : K E E P F U R N I S H I N G S A N D ordinances. OTHER COMBUSTIBLE MATERIALS AWAY FROM THE STOVE AND OUTSIDE MINIMUM NOTICE: Any wall containing combustible CLEARANCES.
  • Page 8: Firebrick Assembly

    Fig. 9a– Step 1, Bottom Firebrick Installation CAUTION: NEVER OPERATE STOVE WITH Two (2) FF-Size; Two (2) T-Size; Two (2) X -Size; MISSING OR CRACKED FIRE BRICKS! One (1) Y-Size; One (1) Z-Size Vogelzang International Corp. Page 8 | DEFENDER™ TR001B | 20120125.0...
  • Page 9: Installation

    LOCATING STOVE continued… A-Size: 9˝x4 ˝x1 ˝ FF-Size: 9˝x4 ˝x1 ˝ M-Size: 9˝x2 ˝x1 ˝ T-Size: 9˝x3 ˝x1 ˝ X-Size: 9˝x4 ˝x1 ˝** Y-Size: 4 ˝x3˝x1 ˝ Z-Size: 3˝x2 ˝x1 ˝ ** X Firebricks are notched for air tube clearance Fig.
  • Page 10: Chimney Sizing

    ENTRY Should you have a problem with inadequate draft, HOLE you should contact a licensed heating and cooling contractor for assistance in solving the problem. Fig.11 - Masonry Chimney Connection Vogelzang International Corp. Page 10 | DEFENDER™ TR001B | 20120125.0...
  • Page 11 CHIMNEY CONNECTIONS If the connector stove pipe must go through a com- bustible wall before entering the masonry chimney, con- sult a qualified mason or chimney dealer. The installation must conform to local building and fire codes and latest edition of NFPA 211 (US) or CAN/CSA-B365 (CDN). If there is a cleanout opening in the base of the chim- ney, close it tightly.
  • Page 12 The stove war- ranty will be void with such an installation. Do not create a hazard in your home by connecting in this manner. FIG. 15 - Fireplace Conversion Vogelzang International Corp. Page 12 | DEFENDER™ TR001B | 20120125.0...
  • Page 13 CHIMNEY CONNECTIONS continued … 8”/203 mm of liner must remain below the entry NOTE: DO NOT ATTEMPT TO ROUTE THE position. When locating the stove and stovepipe, all CHIMNEY CONNECTOR PIPE THROUGH THE minimum clearances must be observed from com- THROAT OF A FIREPLACE.
  • Page 14: Chimney Connection Systems & Clearances

    24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Vogelzang International Corp. Page 14 | DEFENDER™ TR001B | 20120125.0...
  • Page 15: Operating Instructions

    OPERATING INSTRUCTIONS THIS STOVE IS DESIGNED TO BURN CAUTION: HOUSE FIRE HAZARDS WOOD FUEL ONLY! Hardwood, 16”/41cm to 18”/46cm must be air dried • DO NOT STORE WOOD ON FLOOR PROTEC- (seasoned) for a minimum of 6 months. Logs greater TOR, UNDERNEATH STOVEPIPE OR ANY- than 6”/152mm in diameter should be split.
  • Page 16: Starting A Fire, Adding Fuel

    This procedure will prevent wood. unburned gases from igniting causing smoke and flame spillage. 4. Ignite the paper and leave the door open slightly. continued on next page Vogelzang International Corp. Page 16 | DEFENDER™ TR001B | 20120125.0...
  • Page 17: Service Hints

    OPERATING continued . . . SERVICE HINTS 2. When adding fuel be careful not to hit or bump CREOSOTE – FORMATION AND NEED FOR the ceramic baffle board located at the top of the REMOVAL firebox. CAUTION: RISK OF FIRE When wood is burned 3.
  • Page 18: Chimney Draft

    Without the correct amount of draft, the stove will not the first fifteen to thirty minutes after starting the fire. operate properly. Be careful not to over fire the stove. If any part of Vogelzang International Corp. Page 18 | DEFENDER™ TR001B | 20120125.0...
  • Page 19: Glass Care & Replacement

    SERVICE HINTS continued … the stove or chimney starts to glow, you are over 3. Do not build fires against (or that might fall against) firing the stove. Masonry chimneys will take longer the glass. to warm than manufactured chimneys on account of 4.
  • Page 20: Door Gasket Replacement

    AND WHENEVER SERVICING BLOWER ASSEMBLY. NOTICE: ANY REPLACE- MENT WIRING MUST HAVE E Q U I VA L E N T I N S U L A - TION AND TEMPERATURE RATING (105°C). Vogelzang International Corp. Page 20 | DEFENDER™ TR001B | 20120125.0...
  • Page 21: Parts - Defender

    PARTS - TR001B DEFENDER HIGH-EFFICIENCY STOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. 5, 6 5, 6 8, 9, 10...
  • Page 22: Parts - Glass Door

    1B-11T Fire Brick T-size ..........2 1B-11X Fire Brick X-size ........... 1 1B-11Y Fire Brick Y-size ..........1 1B-11Z Fire Brick Z-size ..........2 Fire Brick: Back Fire Brick: Bottom Vogelzang International Corp. Page 22 | DEFENDER™ TR001B | 20120125.0...
  • Page 23: Floor Protector Calculations

    FLOOR PROTECTOR MATERIAL CALCULATIONS This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in the installation instructions on page 6, “Locating Stove” step 1, of this manual. If the floor protector materials listed in the instructions are not available, materials with an equivalent R-value may be substituted.
  • Page 24 “FOR GOD SO LOVED THE WORLD THAT HE GAVE HIS ONLY BEGOTTEN SON, THAT WHOEVER BELIEVES IN HIM SHALL NOT PERISH BUT HAVE ETERNAL LIFE” JOHN 3:16 MADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com...

Table of Contents