Resetting Factory Settings; Calibration; Restoring A Connection With The Base Station (Only Controller Rf); Connecting Extra Rf Sensors (Only Controller Rf) - REMEHA iSense Installation And Service Manual

Digital timer thermostat
Hide thumbs Also See for iSense:
Table of Contents

Advertisement

4. Setting
17
Some settings can only be changed in the mode Extended
mode. The settings you create remain enabled in the
modes Basic mode and Normal mode.
4.3.5.

Resetting factory settings

You can reset all settings, including the clock program, to the works
setting via: Menu > Settings > Users > Reset
4.3.6.

Calibration

You can adjust the measuring value from the inside and outside
sensors via: Menu > Settings > Users > Calibration. This can be
useful if the measured temperatures do not correspond to what you
are used to.
Imagine that the measured temperature is 0,5℃ higher than what you
are used to. You can then enter an adjustment here of -0,5℃.
4.3.7.
Restoring a connection with the base
station (Only controller RF)
When the controller RF or the base station is replaced, you must
restore the connection. To do this, proceed as follows:
1. Put the base station in connection mode. Consult the base station
manual for this.
2. Select in the controller: Menu > Settings > Users >
Connection > Base station.
After a few seconds, the connection is restored.
4.3.8.
Connecting extra RF sensors (Only
controller RF)
1. Set the RF sensor to be connected to connection mode. (Refer to
the documentation for the relevant sensor).
2. In controller RF, select: Menu > Settings > Users >
Connection. Select the correct sensor and press connect. After
a few seconds, the connection is restored.
4.3.9.

Setting the time and date

Set the correct date and time as follows: Menu > Settings > Date/
time.
4 Set time
4 Set date
4 Summer time:
Europe: The controller automatically switches between summer and
winter time.
iSense
030211 - 120666-AG