Battery Life And Replacement; Summary Of Pushbutton Programming Commands - Kaba E-PLEX 2000 Operation Manual

Hide thumbs Also See for E-PLEX 2000:
Table of Contents

Advertisement

Required User Level: Master
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command 500# for Diagnostics.
3. You will see a green LED and hear a high beep followed by a
red LED and a low beep.
4. Enter 123456789*0#, in that order exactly, to test each push-
button. If every pushbutton is working correctly, you will see
a green LED and hear a normal beep for each pushbutton that
is pressed.
5. Example of Complete Entry: 500#123456789*0#.
6. Enter another # to indicate the end of programming.
7. If you see a red LED at any time you are pressing a push-
button, or at the end of the code, there could be a problem with
the pushbuttons.
8. Try the Diagnostic Code again, 500#123456789*0#, to be sure
you entered all the numbers correctly and in the correct order.
9. Enter another # to indicate the end of programming.
10. If you still see the red LED, the lock has a problem. Call a
service person to repair or replace the lock.

Battery Life and Replacement

A variety of factors (shelf life, openings per day, environment, battery
brand, lock settings, etc.) will determine how long your lock operates
on a set of batteries. In average conditions, you can expect a minimum
of 100,000 openings for E-Plex 2000 models with 3 "AA" Alkaline
Batteries.
A Low Battery condition is identified by a flash of both red and green
LEDs when a valid access code is entered and the lock will still give
access. When the low battery condition is observed, the batteries should
be replaced as soon as possible.
26

Summary of Pushbutton Programming Commands

Name
Command
Description of Command
Configure
000 #
'Modify Master User Access Code (lock's
activation)' (Always 8 digits)
MMMMMMMM#
MMMMMMMM#
004 #
'Unlock time setup' (TT = 02 to
20 seconds)
TT#
'Passage Mode Timeout setup' (TT = 01 to
005 #
24 hours - duration time in hours; 00 = no
time limit)
TT#
'Tamper time setup' (TT = 00 to 90 seconds)
006 #
TT#
007 #
'Tamper wrong try setup' (TT = 03 to 09)
TT#
008 #
'Buzzer volume control' (VV = 00 to 03; 00
= off; 01 = Low; 02 = Normal; 03 = High)
VV#
009 #
'Modify access length' (LL = 04 to 08 digits)
LL#
099 #
'Reset to factory default values', except
access code length. (Master, manager and
access user are retained if already pro-
grammed. Users are not reset.)
Authorization
Master
Master, Mgr
Master, Mgr
Master, Mgr
Master, Mgr
Master, Mgr
Master
Master
27