Selecting Fireplace Location - Heatilator I60 Owner's Manual

Woodburning fireplace
Table of Contents

Advertisement

3 3
Framing and Clearances
WARNING
Fire Risk
Provide adequate clearances.• Around air
openings
To combustibles
For service access.
Locate fi replace away from traffi c areas.
A. Selecting Fireplace Location
Several options are available to you when choosing a loca-
tion for your fi replace. This fi replace may be used as a room
divider, installed along a wall, across a corner or used in an
exterior chase. See Figure 3.1.
19-3/8 in.
(492 mm)
42-1/2 in.
(1080 mm)
As a room
divider
48 in.
(1219 mm)
Figure 3.1
Fireplace Locations
60-1/8 in.
(1527 mm)
Across a
corner
45-1/2 in.
(1156 mm)
85 in. (2159 mm)
28 in.
(711 mm)
A
With Outside
Air
Without
Outside Air
Heatilator • I60 US-CAN • 4013-202 Rev F • 11/07
Note:
• Illustrations and photos refl ect typical installations
and are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to
individual design preference.
Hearth & Home Technologies reserves the right to
alter its products.
Locating the fi replace in a basement, near frequently opened
doors, central heat outlets or returns, or other locations of
considerable air movement can affect the performance and
cause intermittent smoke spillage from the front of the fi re-
place. Consideration should be given to these factors before
deciding on a location. See Sections 2 and 10.
A
12 in.
In an exterior chase
(305 mm)
or projecting into a
garage
Along a wall
A
I60
A
in.
49-1/2
mm
1257
in.
45-1/2
mm
1156
1 in. (25 mm) min. distance
Note:
28 in.
from fireplace to
(711 mm)
combustible materials.
Note: In addition to these
framing dimensions,
also reference the
following sections:
• Clearances (Section
3.B.)
• Mantel Projections
(Section 8.C)
• Fireplace Dimensions
(Section 12.A.)
5/8 in. (16 mm)
all configurations
28 in. (711 mm)
9