B. Design and Installation Considerations
NOTICE:
Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
Before installing, determine the following:
-
Where the fireplace is to be installed.
-
The vent system configuration to be used.
-
Gas supply piping.
-
Electrical wiring.
-
Framing and finishing details.
-
Whether optional accessories - devices such as a
fan, wall switch or remote control - are desired.

1. Selecting Fireplace Locations

This fireplace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
Locating the fireplace in a basement should be avoided.
Locating near frequently opened doors, central heat
outlets or returns, or other locations of considerable air
movement can affect the performance.
E
D
As a
room
divider
(1981 mm)
(1219 mm)
MINIMUM
Model #
BIR36
Figure 2.2
Fireplace Locations
6
F
Across a
B
C
corner
G
B
78 in.
48 in.
A
in.
72
mm
1829
Heatilator • Birmingham 36-B Installation Manual • 4059-709 • Rev AB • 06/23
Consideration should be given to these factors before
deciding on a location.
NOTICE: In addition to these framing dimensions, also
reference the following section:
• Clearances (Section 3).
NOTICE:
• Illustrations and photos reflect typical installations and
are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to individual
design preference.
Hearth & Home Technologies reserves the right to alter
its products.
NOTICE:
A minimum 1-1/2 in. air clearance at the back and
a minimum 1-1/2 in. air clearance to the sides of
the fireplace assembly must be maintained.
Chimney sections at any level require a 2 in. mini-
mum air space clearance between the framing
and chimney sections.
B
A*
In an exterior chase
or projecting into a
garage
24 in. (610 mm)
from fireplace opening to
any perpendicular wall
Along a wall
A
B
B
C
D
47 7/8
89 1/8
44 5/8
1216
2264
1133
Note:
1-1/2 in. min. air space
from fireplace to
G
combustible materials.
1/2 in. min. air space at
nailing flanges.
* 12 in. (305 mm) extra space
included for each outside air
connection. If outside air duct
has no bend, this dimension
may be reduced as long as
minimum clearances are met.
1/2 in. (13 mm) all
configurations
G
E
F
G
20 3/8
63 1/8
28 1/2
518
1603
724