B. Clearances
Figure 3.2
10
Fire Risk
Comply with all minimum clearances to combustibles as specifi ed.
Framing or fi nishing material used on the front of, or in front of, the
appliance closer than the minimums listed, must be constructed entirely
of noncombustible materials (i.e., steel studs, concrete board, etc.).
Failure to comply may cause fi re.
Storm Collar
Roof Flashing
2 in. min.
(51 mm)
(attic)
2 in. min.
(51 mm)
Ceiling Firestop
2 in. min.
(51 mm)
0 in.
to floor
Clearances to Combustible Materials
Note: Chimney air kit and 11-10 in./279-254mm adaptor are not shown,
but are required in Canada.
Heatilator • I60 US-CAN • 4013-202 Rev F • 11/07
WARNING
2 in. min.
(51 mm)
Attic
Insulation
Shield
Ceiling Firestop
(ceiling)
2 in. min.
(51 mm)
Offset/Return with
hanger straps
(ceiling)
2 in. min.
Must have 2 in. (51 mm)
(51 mm)
minimum clearance
Adaptor attached here (not shown)
0 in. to level
of standoffs
1 in. (25 mm) to side of appliance
(except at nailing flanges where it is 1/2 in. (13 mm))
to header