Trouble Shooting; Remote Control Trouble Shooting - Emerson SOUTHTOWNE CF4900BS00 Owner's Manual

54” ceiling fan
Table of Contents

Advertisement

BP7485 Southtowne CF4900
!
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLE SHOOTING YOUR FAN.
TROUBLE
1. Fuse or circuit breaker blown.
1. Fan will not start.
2. Loose power line connections to the fan,
3. Reversing switch in neutral position.
2. Fan sounds noisy. 1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Wire connectors inside switch housing
4. Screws holding blades to flywheel
1. Setscrew in motor coupling is loose.
3. Fan wobbles
excessively.
2. Setscrew in hanger ball/downrod
3. Screws securing fan blades to
4. Hanger bracket and/or ceiling outlet
5. Fan blades out of balance.
Fan/Light Fails to Operate
• Check that the speed switch on the fan is set to
(
) or (
) speed.
• Check that the light switch is on.
• Check that the battery is good (blue indicator light
should light when any button is pressed).
• Check that the receiver is wired properly.
• Check that code switches in the remote control and
receiver are set in the same position.
12/4/13
10:15 AM

12. Trouble Shooting

PROBABLE CAUSE
or loose switch wire connections in the
switch housing.
rattling.
are loose.
assembly is loose.
flywheel are loose.
box is not securely fastened.

13. Remote Control Trouble Shooting

Page 26
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit
breakers.
2. Check line wire connections to fan and switch
wire connections in the switch housing.
WARNING: Make sure main power is turned OFF.
!
3. Make sure reversing switch position is all the
way to one side.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing
are snug (not over-tight).
3. Check to make sure wire connectors in switch
housing are not rattling against each other or
against the interior wall of the switch housing.
WARNING: Make sure main power is turned OFF.
!
4. Tighten screws securely.
1. Tighten both setscrews securely in the motor
coupling.
2. Tighten the setscrew in the hanger ball/
downrod assembly.
3. Check to be sure screws which attach the fan
blades to the motor are tight.
4. Tighten the hanger bracket screws to the outlet
box, and/or secure outlet box.
5. Interchanging an adjacent (side-by-side) blade
pair can redistribute the weight and result in
smoother operation.
Short Range
• If the remote control operates the fan when close to
it, but does not operate it at a distance of 40 feet, try
placing the antenna wire outside of the ceiling cover.
26
U.L. Model No.: CF4900

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Southtowne cf4900orb00Southtowne cf4900vs00