What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and
materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you.
If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund
the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE
RESPONSIBLE FOR ALL COSTS OR REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR
OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division
of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air
Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions
or failures caused by:
Repairs by persons not authorized by Emerson Electric Co.,
Use of parts or accessories not authorized by Emerson Electric Co.,
Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
The original purchaser or user ceases to own the product, or
The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and
no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT
RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are
not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or
replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply
to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Part No. F40BP73060001
10:54 AM
Page 1
Net Weight:
Model No.
CF4600WB00
LIMITED WARRANTY
27.1
Lbs.
Form No. BP7306-1

Advertisement

Table of Contents
loading

Summary of Contents for Emerson NOTTINGHAM CF4600GLZ00

  • Page 1 Owner's Manual 27.1 Net Weight: Lbs. Model No. CF4600GLZ00 CF4600WB00 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
  • Page 2: Safety Instructions

    BP7306 Nottingham 3/22/06 10:54 AM Page 2 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
  • Page 3: Unpacking Instructions

    BP7306 Nottingham 3/22/06 10:54 AM Page 3 This Manual is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Tools Needed for Assembly Installed Wire Length Wire Size A.W.G. Up to 50 ft. One Phillips head screwdriver One wire stripper 50-100 ft.
  • Page 4: Electrical Requirements

    BP7306 Nottingham 3/22/06 10:54 AM Page 4 m. One loose parts bag containing: 2. Remove the fan motor and housing assembly from the protective plastic 1. Two 8-32 x 1-1/4” threaded studs bag. Place the fan assembly into the 2. Two 8-32 x 1” threaded studs lower foam pad with the bottom of the 3.
  • Page 5: How To Assemble Your Ceiling Fan

    BP7306 Nottingham 3/22/06 10:54 AM Page 5 Ceiling Fan Procedures WARNING To reduce the risk of personal injury, do General not bend the blade flange when installing Your Emerson ceiling fan comes supplied the blade flanges, balancing the blades or with a Fan/Light Wall Control which cleaning the fan.
  • Page 6 BP7306 Nottingham 3/22/06 10:54 AM Page 6 4. Remove and retain four pan head screws from the rim of the switch cup adapter (Figure 3). 5/32 x 9/16" 5. Position the switch cup assembly on PAN HEAD the switch cup adapter. Line up the SCREWS (2) four holes in the switch cup with the MOUNTING...
  • Page 7 BP7306 Nottingham 3/22/06 10:54 AM Page 7 DOWNROD CLEVIS HAIRPIN CLIP HANGER BALL MOTOR DOWNROD COUPLING SETSCREW Figure 5 8. Separate, untwist and unkink the three motor leads. Route the motor lead 5/16-18 x 1/4" SETSCREW wires through the downrod and seat the downrod in the motor coupling (Figure 9.
  • Page 8 BP7306 Nottingham 3/22/06 10:54 AM Page 8 14. Carefully place the upper housing KNURLED KNOB (2) over the upper glass, making certain LOCKWASHER (2) that the upper glass seats firmly in the 7-WATT upper housing flange. COUPLING (MAXIMUM) COVER CANDELABRA 15.
  • Page 9: How To Hang Your Ceiling Fan

    BP7306 Nottingham 3/22/06 10:54 AM Page 9 18. Position the ceiling cover over the 20. The fan comes with blue, black and downrod and rest it on the upper white leads that are 80” long. Before housing (Figure 10). installing fan, measure approximately 6 to 9-inches above top...
  • Page 10: How To Wire Your Ceiling Fan

    BP7306 Nottingham 3/22/06 10:54 AM Page 10 WARNING WARNING To reduce the risk of fire, electric Failure to seat tab in groove could shock, or personal injury, mount fan cause damage to electrical wires and to outlet box marked “Acceptable for possible shock or fire hazard.
  • Page 11 BP7306 Nottingham 3/22/06 10:54 AM Page 11 1. Position the supply wires to the left side b. Securely connect the supply white (neutral) wire to the receiver white of the outlet box (Figure 14); position (AC IN N) wire. the fan wires to the right side. Partially c.
  • Page 12 BP7306 Nottingham 3/22/06 10:54 AM Page 12 SW101 FAN/LIGHT WALL CONTROL (SUPPLIED) BLACK BLACK (HOT) BLACK LIGHT 120- FAN OFF VOLT WHITE ® EMERSON SUPPLY WHITE WHITE GROUND TWO-CONDUCTOR BLUE WHITE CABLE (WITH GROUND) BLACK GREEN WIRE (GROUND) BLUE FROM HANGER BALL AND WHITE HANGER BRACKET HANGER BALL...
  • Page 13 BP7306 Nottingham 3/22/06 10:54 AM Page 13 Setting Operating Installation of Wall Frequency of Wall Control Control and Receiver SINGLE-POLE INSTALLATION (Figure 17) (Figure 18) Your wall control and receiver have code FAN/LIGHT switches which must be set in one of 16 WALL CONTROL possible code combinations.
  • Page 14 BP7306 Nottingham 3/22/06 10:54 AM Page 14 6. Screw wall control into wall box and 5. Connect one black wire of the wall install decorator style faceplate control to both remaining traveler wires (included). Leave wall control in “OFF” in the wall box and secure with wire mode until fan installation is completed.
  • Page 15: Operating Your Ceiling Fan

    BP7306 Nottingham 3/22/06 10:54 AM Page 15 STANDARD WIRING FOR EXISTING 4. To set the level of housing light 3-WAY CONTROL brightness, press and hold the LIGHT button. The light brightness will EXISTING continue to increase then decrease WALL CONTROL while the button is held down.
  • Page 16: Replacing Light Bulbs

    BP7306 Nottingham 3/22/06 10:54 AM Page 16 Replacing Light Bulbs Attaching Light Kit To replace a burned out light bulb, loosen CAUTION: To reduce the risk of the setscrew in the upper housing and electrical shock, disconnect raise the upper housing/glass enough to electrical supply circuit...
  • Page 17: Instruction To The User

    BP7306 Nottingham 3/22/06 10:54 AM Page 17 Accessories 1. Ceiling Fan Light Kits (see store or WARNING catalog). This product is designed to use only 2. Downrod Extension Kits (see store or those parts supplied with this catalog). product and/or any accessories 3.
  • Page 18: How To Order Repair Parts

    BP7306 Nottingham 3/22/06 10:54 AM Page 18 Repair Parts LIGHT FAN OFF EMERSON Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER •...
  • Page 19 BP7306 Nottingham 3/22/06 10:54 AM Page 19 Repair Parts Listing Part Numbers Model No. Model No. Description CF4600GLZ00 CF4600WB00 Hanger Pack, Consisting of: 761655-51 761655-52 Hanger Bracket — — Hanger Ball — — Downrod — — Parts Bag, Containing: 762290...
  • Page 20: Troubleshooting

    BP7306 Nottingham 3/22/06 10:54 AM Page 20 WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1.