Gas Hobs - Britannia RANGE COOKERS Instruction Manual

Table of Contents

Advertisement

Gas
Gas
THE DUAL WOK BURNER
The central burner of the dual wok burner can be used independently of
the outer burner to give further flexibility.
To light the central burner, press in the control knob and turn it anti-
clockwise to the bold single ring position.
Continue to hold the knob in until the burner lights. Adjust the flame as
required. The minimum setting is the lighter single ring position.
To light the outer burner as well as the central burner, turn the knob to the
bold double ring. Adjust the flame as required. The minimum setting for the
central and outer burner is the lighter double ring position.
LIGHTING THE BURNERS
The symbol above each knob indicates which burner that knob controls.
A flame failure device on each burner acts as a safety gas cut-off in case the
flame is accidentally blown out.
A thermocouple detects the absence of a flame and stops the supply of gas.
The thermocouple must be heated for a few seconds when the burner is ignited before the knob is released.
To light a burner:
1. Push and turn the control knob anti-clockwise to the large flame position. The ignition candle will spark and ignite
the gas.
2. Keep the control knob pressed in for 5-10 seconds to activate the flame failure device, then release the knob. Adjust
the flame between the large and small flame symbols as required.
In the event of a power failure the burners can be lit with a match or gas lighter. The flame failure devices will
continue to function normally.
DUAL BURNER
Use with woks, griddles
and large frying pans
or for large pans and
rapid boiling.
Size
Size
Outer
140mm
Inner
43mm
Power
0.48-5kW
ASSEMBLY OF THE
BURNERS
The circular burners
have two notches, which
fit around the
thermocouple and the
ignition candle (on the
dual wok burner these
notches are located on
the inner ring). Once the
burner is securely in
place, the black burner
cap(s) should sit on top.
The burner caps must be
in the correct position for
operation.
06
RAPID BURNER
Use with large and
medium pans of water
for frying and rapid
boiling.
95mm
Size
Power
3kW
SEMI RAPID
(AND CHEF TOP)
Use for normal frying
and boiling in medium
and small pans.
70mm
Size
Power
1.75kW
BURNER CAP
BURNER RING
ALLOY BURNER BASE
IGNITION CANDLE
FLAME FAILURE DEVICE
SMALL BURNER
Use with smaller pans
for boiling and
simmering and the
preparation of sauces.
Size
50mm
Power
1kW

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF