NTI SERIMUX SERIES CONSOLE SWITCH

Cable Connections

1.
Connect a serial device to the port labeled "CONSOLE" on the SERIMUX using a serial cable with an RJ45 male connector
(see cable specification on page 60). This will be the default administrator device. (Figure 3)
2.
Connect each additional serial device or host to be connected by the SERIMUX to any remaining port (1-8/16/24/32) using a
DTE or DCE type serial cable. The SERIMUX is a DCE type device so all ports are pinned-out accordingly. It may be
necessary to add one of the cable adapters (supplied) detailed in Appendix C (page 62) between the device port on the serial
device or host and the RJ45 connector.
connection of one DCE type device. More adapters can be purchased separately.
Note: There are two types of serial devices, data communication equipment (DCE)(i.e. modem) and data terminal
equipment (DTE) (i.e. CPU), each having different connector pin assignments. The cable adapters (see Appendix C on
page 62) make the proper connections.
3.
Follow the "Initial Startup" instructions on page 8.
32
31
30
16
15
14
NTI
R
NETWORK TECHNOLOGIES INC
1275 Danner Dr, Aurora, OH 44202
RJ45MF-RS232-CO
SERIAL CROSSOVER ADAPTER
(FOR CONNECTION OF DCE
TYPE DEVICE TO SERIMUX)
(Qty 1- supplied)

Connect to the Ethernet

If the Ethernet option is present, the Web Interface (page 36) will be used. An Ethernet connection to the Local Area Network
(LAN) must be made using Cat5 cable with RJ45 connectors attached.
(pin 1 to pin 1, pin 2 to pin 2, etc..) Connect a Cat5 cable between the connector labeled "ETHERNET" and the LAN
(see Figure 4).
32
31
16
15
NTI
R
NETWORK TECHNOLOGIES INC
1275 Danner Dr, Aurora, OH 44202
An NTI RJ45MF-RS232-CO serial crossover adapter has been provided for
Rear View of SERIMUX
29
28
27
26
25
9
13
12
11
10
Tel:330-562-7070
www.networktechinc.com
Ethernet cable
FIREWALL

Figure 3- Connect terminals and devices to SERIMUX Console Switch

Rear View of SERIMUX
28
27
25
30
29
26
9
14
13
12
11
10
Tel:330-562-7070
www.networktechinc.com

Figure 4- Connect the LAN to the SERIMUX

24
23
22
21
20
19
8
7
6
5
4
3
ROUTER
PBX
Wiring between connectors should be straight through
24
23
22
21
20
19
8
7
6
5
4
3
RJ45 male
connector
6
18
17
RESET
ISP
ETHERNET
CONSOLE
2
1
RJ45 Male Connector
USER DEVICE
(VT100, ANSI serial console,
PC w/ Terminal Emulation
Program)
18
17
RESET
ISP
ETHERNET
CONSOLE
2
1
LAN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SERIMUX-CS-x and is the answer not in the manual?

Table of Contents