Mitsubishi Electric FR-A7NL Instruction Manual page 97

Inverter plug-in option
Hide thumbs Also See for FR-A7NL:
Table of Contents

Advertisement

NETWORK VARIABLES
Network variables that allow setting of event driven detection width
Name of Network Variables
Speed monitor (0.005%/bit)
SNVT_lev_percent nvoDrvSpeed
Output frequency monitor
(0.1Hz/bit)
SNVT_freq_hz nvoInvOutFreq
Output frequency monitor
(0.005%/bit)
SNVT_lev_percent nvoInvOutFreqP
Output current monitor (0.1A/bit)
SNVT_amp nvoDrvCurnt
Output voltage monitor (0.1V/bit)
SNVT_volt nvoDrvVolt
Monitor data
SNVT_count nvoInvMonData
Output frequency monitor (0.01Hz/
bit)
SNVT_count nvoInvOutFreq2
90
In/
100% Value
Out
Out
% set reference
Out
frequency
Out
Out Rated inverter current
Rated inverter voltage
Out
(200V class: 200VAC, 400V
class: 400VAC)
The reference value of
100% differs according to
Out
the monitor description.
(Refer to page 61)
% set reference
Out
frequency
Formula of Detection Width
(0.005% increments)
As network variables supported and
SNVT of detection width are the same
type, set the value directly.
Varying width of frequency
monitor value.
% setting reference frequency
As network variables supported and
SNVT of detection width are the same
type, set the value directly.
Varying width of current
monitor value.
Rated inverter current
Varying width of voltage
monitor value.
Rated inverter voltage
Varying width of
monitor data value
Reference value of
each monitor
Varying width of frequency
monitor value.
% setting reference frequency
Refer
to
Page
41
× 100%
46
47
48
× 100%
48
× 100%
× 100%
63
× 100%
64