Configuration Properties; Initial Communication Delay Time (Network Input Config Snvt_Time_Sec Ncipwupouttm) - Mitsubishi Electric FR-A7NL Instruction Manual

Inverter plug-in option
Hide thumbs Also See for FR-A7NL:
Table of Contents

Advertisement

6.8 Configuration Properties

6.8.1
Initial communication delay time (network input config SNVT_time_sec
nciPwUpOutTm)
You can set the time from when the inverter starts until when data is sent to LONWORKS at power-on or
inverter reset.
REMARKS
⋅ The parameter setting is made valid at power-on or inverter reset.
⋅ The delay time at power-on and inverter reset is set and this setting does not affect normal data transmission.
Data Name
nciPwUpOutTm
Parameter
387
Initial communication delay time
⋅ Data acceptance timing ........... At network variable receive (nv_update_occurs event)
Initial Value
Name
Range
0s
0.0s to 120.0s
NETWORK VARIABLES
Increments
0.1s/bit
6
71