6.8.3
% set reference frequency (network input config SNVT_freq_hz
nciInvSetFreqBas)
You can set the reference frequency of "set frequency (nviInvSetFreqP) (Refer to page 45)" and "output
frequency monitor (nvoInvOutFreqP) (Refer to page 47)".
The % set reference frequency can not be set at less than the minimum frequency resolution of the
inverter.
Set frequency reference (nciInvSetFreqBas)
Output frequency of inverter
Frequency written to inverter
Data Name
nciInvSetFreqBas
Parameter
390
% set reference frequency
* 60Hz for the Japanese version and 50Hz for the EC and CH version.
⋅ Data acceptance timing ........... At network variable receive (nv_update_occurs event)
0.00Hz
(0%)
Set frequency (nvilnvSetFreqP)
Initial Value
Name
60Hz / 50Hz *
NETWORK VARIABLES
100.00%
Output frequency monitor (nvilnvOutFreqP)
Range
1.0Hz to 400.0Hz
1.00Hz to 400.00Hz
Increments
0.1Hz/bit
0.01Hz