• Module is not intended as a backup for a slowly discharging battery. The
backup battery will only charge to the level of the primary power source.
If the primary source is slowly decaying, as in a discharging battery, the
backup battery will also slowly discharge. This would render it unable to
provide power when the main source gives out.
• Module may require additional cables if it is not used with a Lind power
adapter that uses detachable cables. Call us for assistance. Lind 12VDC
Battery Backup Module
To connect: Remove the input (cigarette lighter cable or other input con-
nection from the Lind DC adapter and connect this cable to the input of the
Battery Backup Module. Connect the short output cable provided with the
Battery Backup Module between input jack of the Lind DC adapter and the
output jack of the Module. The output cable of the Lind DC adapter will re-
main connected between the device it is powering and the DC adapter. The
input cable, now connected to the LIVCO Module, will remain connected
to the source DC input voltage. The SLA battery connection leads are con-
nected to the SLA battery (+Red Positive) (-Black Negative).This cable is
then connected to the center jack of the Lind Battery Backup Module.