LIND DC Power Adapters Operating Instructions Manual page 114

Dc power adapters
Table of Contents

Advertisement

Battery Voltage Sensing turn-on threshold:
Battery Voltage Sensing timer start threshold: < 13.0 Volts
Ignition ON threshold (if used):
Ignition OFF threshold(if used):
LED Flash rate in timing mode:
Normal timing:
Test Mode timing:
High Battery Voltage disconnect threshold:
Low Battery Voltage disconnect threshold:
Low Battery Voltage disconnect delay:
Input voltage range:
Maximum output current:
Current draw in OFF mode:
Current draw in ON/TIMING mode:
Time Delay adjustment range:
Over-ride Mode time setting:
Test Mode speed up rate:
Lind Electronics, Inc. (LIND) warrants the circuit assembly portion of this product to be free of
defects in material and workmanship for a period of 3 years from the date of purchase under normal
use. During this warranty period, LIND will, at its option, repair or replace the product at no charge
for parts or labor when the product is returned postage paid as a complete unit to LIND. Proof of
purchase and a letter explaining the problem must accompany the returned unit. No refund or ex-
changes on specially designed products.
This warranty does not apply if the product has been altered or subjected to abuse, accident or
misuse. This warranty excludes incidental or consequential damage resulting from the product or
the use of the product. This warranty is in lieu of all other warranties expressed or implied and no
person is authorized to assume for LIND any other liability in conjunction with this product. The
warranty gives you, the purchaser, specific legal rights and you may have other rights which may
vary from state to state and country to country.
The LIND product you are purchasing has not been designed for, or certified for use in, life support
applications. Any such use is at your own risk. LIND ELECTRONICS, INC. HEREBY EXPRESS-
LY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE. Lind Electronics, Inc. will not be liable for any claims, awards, dam-
ages or other liability arising out of the use of LIND products for life support applications whether
in the nature of direct, indirect, consequential, special or punitive damages.
SHUT DOWN TIMER SPECIFICATIONS
Limited Warranty
> 13.5 Volts
> 5 Volts
< 2.5 Volts
2 Seconds
.5 Seconds
> 18 Volts
< 10.5 Volts
> 10 Seconds
9-18 Volts
30 Amps
18 mAmps
95 mAmps
5 Sec.- 4 Hrs
12 Minutes
{over-rides time adj. setting}
x 100