Upgrading Accessory Devices Via An Ip Address - AMX Modero NXD/NXT-1200VG Operation/Reference Manual

Vg series modero touch panels
Table of Contents

Advertisement

Upgrading Modero Firmware
8.
Enter the Device value associated with the panel and the System number associated with the Master
(listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.
9.
Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update
process is complete. The reboot of the panel can take up 30 seconds after the firmware process has
finished.
10.
Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog
(FIG. 97).
11.
Click Close (after the panel reboots) to return to the main program.
12.
Right-click the associated System number and select Refresh System. This causes a refresh of all project
systems, establishes a new connection to the Master, and populates the System list with devices on your
particular system.

Upgrading Accessory Devices via an IP Address

The following accessory devices are firmware upgradeable:



These devices are not given a unique device numbers which would ordinarily appear within the Online Tree
tab of NetLinx Studio. They appear below the target which they are either communicating with (NXA-AVB/
RGB) or a part of (NXA-BASE/B or NXA-RGB card) as seen below in FIG. 98.
NetLinx Studio Online Tree tab
FIG. 98
Location of Firmware version information within NetLinx Studio
The only way to upgrade the firmware of an accessory item is to send the accessory's firmware through a
target panel. Its this panel's device number which is entered within the Send to NetLinx Device transfer dialog
in Studio.
Firmware can also be downloaded to accessory items via a direct USB connection
using the PC as a Virtual Master (Upgrading the Modero Firmware via the USB
port section on page 109). In this case, you will still need to know the System and
Device Number information of the target panel. For a more detailed description of
how to setup this type of connection, refer to the Configuring and Using USB with a
Virtual Master section on page 87.
116
NXA-BASE/B Battery Base (FG2255-10)
NXA-RGB card (FG2260)
NXA-AVB/RGB Breakout Box (FG2254-11)
Target Panel Device #
NXA-RGB
firmware
NXA-AVB/RGB
(BOB version)
Accessory's corresponding firmware page