3.
Press the System Number field to launch a Keypad and enter the value for the system number of the
NetLinx Master. This value can be obtained from the NetLinx Studio program > OnLine Tree of the
Workspace window.
4.
Do not alter the IP Settings section, of the System Settings page, as these fields are not applicable to this
connection mode.
5.
Enter a username and password (into their respective fields) if the target Master has been previously
secured.
6.
Press the on-screen Reboot button to both save any changes and restart the panel.
7.
Press the grey Front Setup Access button for 3 seconds to open the Setup page and confirm there is an
active connection.
The NetLinx Master and the Modero panel must both be on the same Subnet.

Using G4 Web Control to Interact with a G4 Panel

The G4 Web Control feature allows you to use a PC to interact with a G4 enabled panel via the web.
This feature works in tandem with the new browser-capable NetLinx Security firmware update (build 300 or
higher). G4 Web Control is only available with the latest Modero panel firmware.
Refer to the G4 Web Control Settings section on page 153 for more detailed field information.
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from www.amx.com. Refer to your NetLinx Master Instruction
Manual for more detailed information on the use of the new web-based NetLinx
Security.
1.
Press the grey Front Setup Access button for 3 seconds to open the Setup page.
2.
Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup
page and display an on-screen keypad.
3.
Enter 1988 into the Keypad's password field (1988 is the default password).
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
4.
Press Done when finished.
5.
Press the G4 Web Control button to open the G4 Web Control Settings page (FIG. 87).
FIG. 87
G4 Web Control page
6.
Press the Enable/Enabled button until it toggles to Enabled (light blue color).