Premium Leisure Swimmer’s Edge 18 Owner's Manual page 49

Premium leisure swim spas owner’s manual
Table of Contents

Advertisement

MESSAGE
MEANING
ICE
Potential freeze condition
IC
detected (Ice)
SnA
Sensor A is not working
SA
correctly. Swim spa is shut
down.
SnB
Sensor B is not working
SB
correctly. Swim spa is shut
down.
SnS
Sensors are out of balance.
Sn
HFL
A substantial difference
HL
between sensors was
detected (possible flow
problem).
LF
Low Flow – persistent
problem. Displays after the
fifth occurrence of the "HL"
message within 24 hours.
Heater shuts down but
other swim spa functions
run normally.
dr
Inadequate water, poor
flow, or air bubbles
detected in the heater.
Swim spa is shut down for
15 minutes.
drY
Inadequate water detected
dy
in heater. Displays on third
occurrence of "dr"
message. Swim spa is shut
down.
ACTION REQUIRED
No action required. The pump will
automatically operate regardless of
the swim spa status.
Check the sensor "A" plug
connection to circuit board. The
problem may appear temporarily in
an overheat situation and disappear
when the heater cools. If the
problem persists, contact service.
Check the sensor "B" plug
connection to circuit board. The
problem may appear temporarily in
an overheat situation and disappear
when the heater cools. If the
problem persists, contact service.
If this alternates with the
temperature, it may be temporary. If
the display shows only this
message (periodically blinking), the
swim spa is shut down .If the
problem persists, contact service.
Check water level in swim spa and
add water if necessary. Be sure that
slide-valves are open. Make sure
the pump is primed and has power.
If the problem persists, contact
service.
Heating ability of the swim spa will
not reset automatically; press any
button to reset.
Check the water level and add
water if necessary. Be sure that
slide-valves are open. Make sure
the pump is primed and has power.
Press any button to reset
(automatically reset within 15
minutes). If the problem persists,
contact service.
Check water level in swim spa. Add
water if necessary. Be sure that
slide-valves are open. Make sure
the pump is primed and has power.
Press any button to reset.
Page 47
For HELP, call 727.573.9611

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swimmer 18Dual zone 18Swimmer 14

Table of Contents