3.
Turn the power on at the main breaker. The LED display will show two
red lights. Using the handheld remote control (see page 40), press t
ON/OFF button. The system will come on and the LED readout will
automatically go to 50. Let the system run for 2-3 minutes to pressurize
itself. (NOTE: If the system does not turn on, check the LED readout to
see if it reads
"LOW OIL." If so, follow the instructions for Low Oil Shut
Off (below).
4.
Shut the system off and check for any leaks that make have occurred
during shipme
nt. The fluid level should have dropped as it pressurized
the hoses.
5.
Fill the tank until the fluid reaches 260 in the sight glass. Your system is
now ready to restart. We recommend maintaining you
in the sight glass. Periodically check your fluid level.
6.
Using the handheld remote control, turn your system
the flow to 100-150 and let it run for 5-10 minutes.
NOTE: There is an automatic shut off built in to the Swimmer's Edge 18 swim
spa. The hydraulic system will run for 30 minutes and shut
si
mply turn it back on using the handheld remote control.
Low Oil Shut Off
The low oil shut off valve is located on the top of the aluminum tank, next to the
fill cap. If your system is low on oil, the LED digital readout will indicate "LOW
OIL." You must turn the system off at the breaker and wait 5 minutes before
turning it back on. This will reset the program. Fill the tank until the fluid reaches
2
00 in the sight glass. Turn the power back on at the breaker.
Bleeding Air from the Pressure Line
When you turn your power unit on and the flow head (water current) does not
come on, you must bleed your pressure system (yellow line). With the system
running, slowly loosen the yellow pressure hose fitting. Air will escape. Once all
th
e air has escaped, the flow head will spin and the current will resume.
Startup and Maintenance
The Swimmer's Edge 18 is full and ready for swimming when the water le
reaches ½ inch to 1 inch above the flow head wh
p
roduced. (About level with the metal grab rail).
NOTE: A low water level can result in filtration and heating problems. Regularly
"top off" your Swimmer's Edge 18 swim spa with a nearby
w
ater level could cause excess overspill and splash out.
Once your Swimmer's Edge 18 is full an
q
uality system can be started.
Set your filtration mode to your desired setting (see page 32) and set your water
temperature (see page 31) to your desired setting (we recommend 80 degr
or 27 C, for swimming). It could take 36 to 48 hou
ere the water current is
d all connections are made, the water
rs to reach your desired
Page 26
For HELP, call 727.573.9611
he
r fluid level at 260
on and increase
off. If this happens,
vel
garden hose. A high
ees F,