PROBLEM
CAUSE
Moved my
Wiring error at
swim spa and
GFCI
now it doesn't
No power to
work
swim spa
Nothing
Breaker has
works
tripped
Fuse blown
Pump not
No power to
running
swim spa
Water does
Air lock
not flow
Closed jets
ACV open
Water too hot
High set
temperature
High ambient
temperature
Water will not
Thermostat is
heat
set too low
Air open
Dirty filter
Blown fuse
Slide valve
closed
Cover off
Swim spa in
Economy
mode
Common Error Codes:
MESSAGE
MEANING
(none)
No message on display.
Power has been cut off to
swim spa.
OHH
The swim spa has shut
HH
down from high heat
detection. One of the
sensors detected 118ºF
(48ºC) at the heater.
OHS
The swim spa has
OH
overheated and shut down.
One of the sensors
detected that the swim spa
water is 110ºF (43ºC).
Check Neutral wiring of GFCI (see diagrams
on pages 10-22)
Reset circuit breakers on GFCI panel and
main circuit breaker panel
Check and reset breaker. If problem
persists, check for loose electrical
connections. Check for Neutral wiring error
at GFCI.
Check for blown fuses inside of spa pack.
Reset circuit breakers on GFCI panel and
main circuit breaker panel
Bleed air from the system (page 43-44)
Open all jets by turning counterclockwise
Close air control valves
Turn down set temperature on topside
control panel
Remove the cover
Check and reset to desired temperature
Close air control valve
Check and clean filter
Check and replace fuse
Check and open all valves
Put the cover back on
Press the Standby button and take out of
Economy
ACTION REQUIRED
The control panel is disabled until
power returns. Swim spa settings
are preserved.
Do not enter the water. Remove the
cover and allow the water to cool.
Once cool, push any button. If the
swim spa does not reset, turn off
the GFCI and call service.
Do not enter the water. Remove the
cover and allow the water to cool. At
107ºF (42ºC), the swim spa resets
automatically. If the swim spa does
not reset, turn off the GFCI and call
service.
Page 46
For HELP, call 727.573.9611
SOLUTION