15 minutes and the low speed of Pump 1 automatically will turn off after 4 hours.
The low speed of Pump 1 runs when the "AUX" Pump 2 (if equipped) is on. It
may also active for at least two minutes every half hour to detect the swim spa
temperature and then to heat to the set temperature if needed (depending on
mode). When the low speed turns on automatically, it cannot be deactivated from
the panel, however the high speed may be activated.
Aux Button
Press the "AUX" button once to turn on Pump 2 (if equipped). Press it a second
time to turn off Pump 2. If left running, Pump 2 automatically will turn off after 15
minutes.
Light
Press the "LIGHT" button once to turn on your swim spa lights. Press the LIGHT
button multiple times to cycle through the many available color patterns. Press
the LIGHT button again to turn off the LED light system. If left on, the lights
automatically turn off after 4 hours.
Mode
Your swim spa operating mode is changed by first pressing the "WARM" or
"COLD" button, then pressing the "MODE" button.
Standard Mode is programmed to constantly maintain the desired
temperature. "Std" will be displayed momentarily when you switch into
standard mode.
Economy Mode heats the spa to the set temperature only during filter
cycles. "Ecn" will display solid when temperature is not current and will
alternate with temperature when temperature is current.
Sleep Mode heats the swim spa to within 20°F/10°C of the set
temperature only during filter cycles. "SLP" will display solid when
temperature is not current and will alternate with temperature when
temperature is current.
Preset Filter Cycles
The first filter cycle begins six minutes after the swim spa is energized. The
second filter cycle begins 12 hours later. Filter duration is programmable for 2, 4,
6 or 8 hours – or for continuous filtration indicated by "FI LC." The default filter
time is two hours.
To program filter cycles, press "WARM" or "COOL" and then "JETS." Press
"WARM" or "COOL" again to adjust to your desired setting. Press "JETS" again
to exit filter cycle programming.
The low speed of the 2-speed pump runs during filtration and the ozonator will be
enabled.