Only if pushing this button successfully trips this
reset this breaker and proceed to the next step.
2.
Go to the topside control panel. The swim spa first goes into a 6-minute
Priming mode, indicated by "Pr" message. Water heating is disabled during
priming. To exit Priming mode and begin normal swim spa operation, press
"Up" or "Dow
n" button. The circulation pump starts and water flows through
the returns.
3.
Press the Jets 1 button. You should hear the pump turn on high speed, se
water
circulating, and see the Jets 1 icon spin on the information display
area.
Caution
: If water is not flowing from the jets after 2 minutes, turn the
power off at the main panel and bleed air from the system (see
page 43-44). Turn the power on again. Sometimes momentarily
turning the pump off/on will help to prime. Only do this 4 times.
4.
If the water is running smoothly through the lines, open the air control valve
to the jets and you should see an increase in jet pres
the water and airflow of every river jet if necessary.
An air mixture intensifies the level of your current. Turn the air control val
counterclockwise to increase the air mixture and clockwise to turn it off.
To minim
ize heat loss, close the air control valve when the swim spa is not
in use.
5.
Press the Jets 1 button a second time to turn off the pump.
6.
Press the Jets 2 button. You should hear the pump turn on, see water
circulating, and see the Jets2 icon spin on the inform
7.
Press the Jets 2 button again to turn off the pump.
8.
Press the AUX button. You should hear Pump 3 turn on, see
and see the AUX icon spin on the information dis
9.
P
ress the AUX button again to turn off Pump 3.
Operational Checks: All Models (Spa Side)
Caution: D
o not turn on any pump until your swim spa is properly filled with
water. Running any pump without water in your swim spa can
cause IMMEDIATE damage, which is not covered under warranty!
By now you have rechecked your unit's mechanical connections and filled it wi
water to the recommended level). Turn on power to the swim spa at the main
breaker panel and test the operation of the electrical system. If you
problem, please reference the troubleshooting guide on page 45.
1.
Turn on the breaker and test the operation of the Ground-Fault Circuit
Interrupter (or RCD) breaker by pushing the small
automatically trip the swim spa's circuit breaker.
Page 28
For HELP, call 727.573.9611
circuit breaker should you
sure. Check and adjust
ve
ation display area.
water moving,
play area.
encounter a
button. This should
e
th