Check License key
Check Master Slave
Check that the link has not been further obscured or the ODU misaligned.
Check the DFS page at each end of the link and establish that there is a quiet wireless
channel to use.
If there are no faults found in the configuration and there is absolutely no wireless signal retry
the installation procedure. If this doesn't work then the ODU may be faulty.

10.2.2 Some Activity

If there is some activity but the link is unreliable or doesn't achieve the data rates required
then:
Check that the interference has not increased using the i-DFS measurements
If a quieter channel is available check that it is not barred
Check that the path loss is low enough for the communication rates required
Check that the ODU has not become misaligned