Enviro EG40 DV Owner's Manual
Hide thumbs Also See for EG40 DV:

Advertisement

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
OWNER'S MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
If the information in this manual is not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life. Installation and
service must be performed by a qualified installer, service agency or the gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline or other Flammable vapours and
liquids in the vicinity of this or any other appliance.
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas fitter when installed within the Commonwealth of Massachusetts. Other
Massachusetts code requirements: Flexible connector must not be longer than 36in., a
shut off valve must be installed; only direct vent sealed combustion products are approved
for bedrooms/bathrooms. A carbon monoxide detector is required in all rooms containing
gas fired direct vent appliances.
EG40 DV
B Y : S H E R W O O D I N D U S T R I E S L T D
WHAT TO DO IF YOU SMELL GAS
• Open windows/Extinguish any open flame.
• Do not try to light any appliance.
• Do not touch any electrical switch or use any
phone in your building.
• Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
This appliance may be installed in an after market
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
WARNING
certified kit is used.
EG40-070

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EG40 DV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enviro EG40 DV

  • Page 1 SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. EG40 DV B Y : S H E R W O O D I N D U S T R I E S L T D OWNER’S MANUAL...
  • Page 2: Safety Precautions

    Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it.
  • Page 3: Table Of Contents

    Table of Contents Safety Precautions................2 Table of Contents.................3 Codes And Approvals................4 Specifications..................5 Dimensions................5 Rating Label Location..............5 Operating Instructions.................6 Lighting Instructions..............6 Normal Sounds During Operation..........7 Adjusting The Venturies.............7 Maintenance and Service..............8 Opening The Door..............8 Cleaning The Glass..............8 To Replace Door................8 Cleaning The Firebox..............8 Cleaning Plated Surfaces............9 Burner Removal................9 Replacing The Blower..............9...
  • Page 4: Codes And Approvals

    After the unit has gone through the first burn turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.
  • Page 5: Specifications

    Specifications imensions " (318 mm) " (117 mm) 21" (533 mm) " (740 mm) 25" (635 mm) Shipping Weight 256 lbs (116 kg) Figure 1: EG40 Exterior Dimensions. ating abeL ocation The rating label is found inside the right cabinet side panel.
  • Page 6: Operating Instructions

    Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. ighting nstRuctions CAUTION: Hot while operating. Do not touch, severe burns may result. Keep children, clothing, furniture, gasoline or other flammable vapors away. CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air.
  • Page 7: Normal Sounds During Operation

    Operating Instructions Thermopile Thermocouple Figure 3: Pilot Burning. Figure 4: Gas Valve. Djusting entuRies • There is a separate venturies for each burner, Rear log holder see Figure 5. Front log holder • Remove one screw from the cover plate located Ember tray &...
  • Page 8: Maintenance And Service

    Depending upon the amount of use, cleaning should be required no more than two or three times per season. To clean the door, use a mild glass cleaner and a soft cloth or a glass cleaner available from your Enviro dealer. Abrasive cleaners will damage the glass.
  • Page 9: Cleaning Plated Surfaces

    Maintenance and Service 3. Vacuum the bottom of the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner. 4. After carefully replacing the log and embers in their correct positions (see Secondary Installation - Installation of Log Set and Embers), and the door has been resealed, re-light the pilot, following the instructions on the lighting label attached to the unit.
  • Page 10: Fuel Conversion

    Maintenance And Service onVeRsion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 11 Maintenance And Service Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 9. b) Insert a ” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 10), rotate it counter-clockwise until it is free and extract it.
  • Page 12: Initial Installation

    Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. RepaRation nstaLLation • Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible.
  • Page 13: Planning Your Installation

    Initial Installation QUALIFIED INSTALLERS ONLY Lanning nstaLLation When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10 inches (25.4 cm), 1½...
  • Page 14: Corner Installations

    Initial Installation QUALIFIED INSTALLERS ONLY oRneR nstaLLations Outside or Do not interfere with the structural integrity of Inside Wall the walls. Outside Wall Figure 16: Corner installation top vented. obiLe nstaLLation • When the unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a grounding rod.
  • Page 15: Vent Termination Restrictions

    Initial Installation QUALIFIED INSTALLERS ONLY eRmination estRictions Fixed Closed Fixed Openable Closed Openable Termination Cap Air Supply Inlet Gas Meter Restriction Zone (Termination not allowed) Figure 18. Vent Termination Restrictions, refer to Table 2. Table 2: Vent termination clearances, refer to Figure 18. Letter Canadian Installation US Installation...
  • Page 16: Freestanding Direct Vent Kit With Coupler

    Initial Installation QUALIFIED INSTALLERS ONLY ReestanDing iRect oupLeR KIT COMPONENTS: Quantity Description Quantity Description Horizontal direct vent termination cap Wall Thimble Flue collar adapters (only one used) Wire spacers T-20 Torx screws Decorative rings Ø6⅝” (17 cm) 90° elbow 4 oz tube RTV silicone Inside finish trim collar ”...
  • Page 17 Initial Installation QUALIFIED INSTALLERS ONLY 11. Stretch the liner out. Attach the flexible liner to the vent termination cap by placing a small bead of high temperature silicone on the vent termination and slide the flex liner onto the vent terminal and secure with three (3) sheet metal screws evenly spaced.
  • Page 18: Other Approved Vent Parts

    Initial Installation QUALIFIED INSTALLERS ONLY 16. Slide the 90° elbow over the flex pipe. Do not slip the outer sections of pipe together, you will require some movement in these pipe section in order to secure the flex pipe to the flue outlet on the appliance.
  • Page 19 Initial Installation QUALIFIED INSTALLERS ONLY Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct-Temp Secure Vent Ameri Vent Description Direct 4DT-6 SV4L6 6” pipe length 7” pipe length 4DT-9 9” pipe length 4DT-12 SV4L12 4D12...
  • Page 20: Vent Configurations

    Initial Installation QUALIFIED INSTALLERS ONLY onFiguRations Figures 22 shows the range of venting options, it shows possible vent configurations if the unit is top vented, for vertical and horizontal terminations, any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement.
  • Page 21: Horizontal Installation

    Initial Installation QUALIFIED INSTALLERS ONLY oRizontaL nstaLLation 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance.
  • Page 22 Initial Installation QUALIFIED INSTALLERS ONLY 4. Position the horizontal vent termination in the center of the 10” (25.4 cm) x 10” (25.4 cm) hole, and attach to the exterior wall with the four screws provided. Before attaching the vent termination to the exterior wall, run a bead of non-hardening mastic around the edges, so as to make a seal between the termination and the wall.
  • Page 23: Vertical Installation

    Initial Installation QUALIFIED INSTALLERS ONLY eRticaL nstaLLation 1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. Do not pack air spaces with insulation. 2. Set the gas appliance in the desired location. Ceiling Joist Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark...
  • Page 24 Initial Installation QUALIFIED INSTALLERS ONLY support straps to the roof. Seal the nails holes heads with non-hardening mastic. Trim the excess length of the support straps that extend out beyond the edge of the flashing. 7. Slip the flashing over the pipe section protruding through the roof. Secure the base of the flashing to the roof with roofing nails.
  • Page 25: Cathedral Ceiling Installation

    Initial Installation QUALIFIED INSTALLERS ONLY • For multi story installations. A ceiling firestop is Nails required at the second floor, and any subsequent Ceiling firestop floors (see Figure 33). The opening should be framed to 10” (25.4 cm) x 10” (25.4 cm) inside dimensions, in the same manner as shown in Figure 29.
  • Page 26: Venting Into A Class 'A' Chimney

    Initial Installation QUALIFIED INSTALLERS ONLY ‘a’ c enting into a Lass himneY This model is also certified and tested to vent into CLASS ‘A’ wood stove chimneys. Place the freestanding direct vent appliance in the desired location. Use a conversion kit from Simpson Duravent (931, 932, or 933), or Security Chimney (SV4CCK1, SV4CCK2, or SV4CCK1).
  • Page 27: Electrical Requirements

    LectRicaL equiRements The ENVIRO EG40 will operate without electrical power. This model has a millivolt gas control, which uses the pilot flame to generate enough electricity to operate the main burners. The appliance is equipped with a blower and must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY...
  • Page 28: Gas Line Connection And Testing

    Initial Installation onnection anD esting WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in a ⅜”...
  • Page 29: Secondary Installation

    If over time, through cleaning and servicing, these embers require replacement, contact the nearest ENVIRO dealer for replacement Figure 30: Step 1 of Log Placement. embers. Pins for Rear Log The embers can be place before or after the logs are placed.
  • Page 30 Secondary Installation Ledge for Right Log Place the log set into the firebox. Locate each log by seating it down onto the burner tray support pins. Follow Figures 31 to 34 proper log placement. Upon the first light up, watch for Pin for Right Log ignition to ALL burner ports.
  • Page 31: Trouble Shooting

    Trouble Shooting Problem Possible Cause Solution The main burner does not The gas valve may not be on. • Check that the gas control knob is in the “ON” position. ignite when called for. Thermostat is not calling for • Adjust the thermostat several degrees above ambient heat.
  • Page 32: Parts List

    Parts List Reference Part Description Part Number Number 120 °F (49 °C) Ceramic Temperature Sensor EC-001 S.I.T. NOVA Valve Convertible 50-1421 Thermocouple EC-009 Spark Electrode with Ignitor Cable EC-011 Thermopile EC-012 Fully Assembled Pilot NG EC-015 Fully Assembled Pilot LP EC-016 Pilot Orifice NG Threaded EC-019...
  • Page 33 Parts List Reference Part Description Part Number Number Side Panel EG40-086 DV Stove Top EG40-087A Firebox Baffle EG40-088 Stove Top Baffle DV EG40-091A Venturi Cover Plate EG40-097 Front Venturi EG40-098 Bar Set - Painted (3 pieces) EG40-114 Bar Set - Gold (3 pieces) EG40-115 Bar Set - Nickel (3 pieces) 50-478...
  • Page 34: Parts Diagram - Chassis

    Parts Diagram - Chassis EG 40 Body (Chassis) July 2004...
  • Page 35: Parts Diagram - Gas Tray & Door

    Parts Diagram - Gas Tray & Door...
  • Page 36: Warranty

    Sherwood Industries Ltd. (“Sherwood”) hereby warrants, subject to the terms and conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail.
  • Page 37: Installation Data Sheet

    � NATURAL GAS (NAT) PROPANE(LPG) _________________________________________ INLET GAS PRESSURE:_________in wc PHONE:___________________________________ MAIN BURNER ORIFICE:__________# DMS PILOT ORIFICE #_________OR________in diam. INSTALLER’S SIGNATURE: _________________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com January 22, 2013 C-13838...

Table of Contents