Page 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 28 B Vented O W N E R S M A N U A L WHAT TO DO IF YOU SMELL GAS • Open windows •...
FOR SAFE INSTALLATION AND OPERATIONOF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL • Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at once least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
Safety Precautions Code Approvals Deciding where to locate your stove Venting Installation of Log Sets and Embers Operating Instructions Maintenance and Technical Trouble Shooting Gas Line Connection Electrical Parts and Accessories Fuel Type Conversion Warranty Parts List Exploded Views Installation Data Sheet •...
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: Front Width: 22"/ 56cm Rear Width: 22"/ 56cm Height: 27-1/2"/ 70cm* Depth 19"/ 48cm (*not including vent coupling) Shipping Weight: 210 lbs/95 kg CLEARANCES: A. Side wall to stove 10"/ 25cm B. Rear wall to stove C.
VENT TERMINAL CLEARANCES Figure 3 A= Clearance above grade, verandah, porch, deck, or [balcony (*12 inches (30cm) minimum] B= Clearance to window or door that may be opened [*12 inches (30cm) minimum] C= Clearance to permanently closed window [minimum 12 inches (30cm) recommended to prevent condensation on window] D= Vertical clearance to ventilated soffit located above the terminal within a horizontal...
This model must have a vent opening in the rear of the unit. Confirm this and also check that the label on the right side panel door states "Vented Room Heater". WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM.
A. USING AN EXISTING CHIMNEY • Measure the height of the chimney beforehand and purchase the appropriate kit. Never attempt to over stretch a flexible liner to accommodate the height of the chimney. • Any flue damper must be removed or locked permanently in the open position.
INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBERS A bag of Rock Wool embers is provided for use on the burner tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required.
OPERATING INSTRUCTIONS WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by hand by following these instructions exactly. B) BEFORE LIGHTING smell all around the appliance area for gas, and next to the floor because some gas is heavier than air and will settle on the floor.
MAINTENANCE AND TECHNICAL Annually check to ensure that your Venting system is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with small yellow tips.
Page 11
Problem Spark will not light the pilot after repeated pressing of spark igniter Pilot will not remain lit Burners will not remain lit Flame lifting Glass fogs up Blue flames Flames are burning “dirty” or Sooting Possible Cause Defective piezo igniter Broken spark electrode Miss-aligned spark electrode Problem with thermocouple circuit...
ORIFICE SIZES, PRESSURE AND BTU’S Orifice size Manifold pressure. Min. Manifold pressure. Supply Pressure. Min. Supply pressure. Max. BTUH Input. Min. BTUH Input. Output fan off Output fan on WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. NOTE: The gas line connection may be made using 3/8"...
Page 13
The ENVIROGAS EG 28.FS.BV. will operate with no external power supply. These models have a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burner. The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE.
Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve Piezo Igniter Burner Switch B-vent Spill switch 220° Orifice Blank Gold trim Package Low Voltage Thermostat REMOVING or INSTALLATION OF THE BLOWER 1.
ADJUSTING THE VENTURI • Remove the ash shelf by undoing the screw at each end, pull shelf towards you. • Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.
Because of our high standards Sherwood Industries Ltd. can offer a *Lifetime Warranty on all it’s gas products. Covered under this warranty are Cabinet Sides, Tops, Pedestals, Surround Panels and Chassis. These steel components are covered against manufacture’s defects for 5 years and labour for the first years and for parts only thereafter.
EC-001 120° F CERAMIC TEMP SENSOR EC-002 220° F CERAMIC SPILL SWITCH EC-006 SIT NOVA 820 NG VALVE 50% EC-007 SIT NOVA 820 LP VALVE 50% EC-009 THERMOCOUPLE (POST 10/00) EC-011 SPARK ELECTRODE w/CABLE EC-012 THERMOPILE EC-013 PILOT NG w/ELECTRODE EC-014 PILOT LP w/ELECTRODE EC-015...
BV 4” CRIMPED 120 ° F (49° C) FLUE PIPE CERAMIC FAN EG28-169 TEMP SENSOR DV 4” EC-001 FLARED FLUE PIPE EG28-170 CONVECTION BLOWER EC-030 FS FAN MOUNTING BRACKET EG28-304 WIRE CHANNEL EG28-139 220° F (104° C) CERAMIC SPILL SWITCH EC-002 1 X 1 SIDE CABINET...
Page 19
PAN BURNER TOP BURNER CONTROL ASSEMBLY COMPLETE EG28-143 NG EG28-145 LPG VENTURI TUBE BURNER BRACKET ORIFIC BLANK EC 022 CONTROL PANEL FS FAN CONTROLLER EC-038 EG28 DOOR AND GAS TRAY ASSEMBLY EXPLODED Page 1 of 2 FULLY ASSEMBLED PILOT EC-015 NG , 016 LP THERMOPILE EC-012 THERMOCOUPLE...
INSTALLATION DATA SHEET The following information must be recorded by the installer for warranty purposes and future reference. Model: EG 28 B vented Name of Owner: __________________________________________ Address: __________________________________________ __________________________________________ __________________________________________ Phone:_____________________________________ • Model :___________________________________ • Serial Number: __________________ • Date of Purchase: __________/________/________ •...