SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
OWNER'S MANUAL
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch or
use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapours and liquids in the
vicinity of this or any other appliance.
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life. Installation and service must be
performed by a qualified installer, service agency or the gas supplier.
WARNING
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas fitter when installed within the Commonwealth of Massachusetts.
Other Massachusetts code requirements: Flexible connector must not be longer than
36in., a shut off valve must be installed; only direct vent sealed combustion products
are approved for bedrooms/bathrooms. A carbon monoxide detector is required in all
rooms containing gas fired direct vent appliances.
FOCUS
B Y : S H E R W O O D I N D U S T R I E S L T D
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
EG31-118

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FOCUS EG31-118 and is the answer not in the manual?

Questions and answers

Summary of Contents for Enviro FOCUS EG31-118

  • Page 1 SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE OWNER’S MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows/extinguish any open flame. • Do not try to light any appliance. •...
  • Page 2: Safety Precautions

    Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to commencing the installation.
  • Page 3: Table Of Contents

    Table of Contents Safety Precautions...2 Table of Contents...3 Codes And Approvals...4 Specifications...5 Dimensions...5 Rating Label Location...5 Operating Instructions...6 Lighting Instructions...6 Adjusting Venturi Air Settings...7 Blower speed...7 Normal Sounds During Operation...7 Maintenance And Service...8 Routine Maintenance...8 Glass Door Removal...8 Cleaning The Glass...8 Cleaning The Firebox...8 Replacing the Glass...8 Maintaining Fascia And Surround Finishes...9...
  • Page 4: Codes And Approvals

    CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO FOCUS Fireplace: • Has been certified for use with either natural or propane gases. (See rating label.) • Is not for use with solid fuels.
  • Page 5: Specifications

    WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. IMENSIONS " (77cm) 18" (45.7cm) " (30.6cm) 42" (106.7 13 1⁄4" (33.7cm) ATING ABEL OCATION The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace.
  • Page 6: Operating Instructions

    Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. IGHTING NSTRUCTIONS Hot while operating. Do not touch, severe burns may result. Keep children, clothing, CAUTION: furniture, gasoline or other flammable vapors away.
  • Page 7: Adjusting Venturi Air Settings

    Operating Instructions DJUSTING ENTURI ETTINGS There is only one (1) venturi and one (1) air shutter to be adjusted. When installing the burner top, ensure that the venturi tube is engaged to the air shutter adjustment rod. Use this small venturi adjustment rod to achieve a proper and efficient flame, shown in Figure 5.
  • Page 8: Maintenance And Service

    Replace the logs and embers as in the ECONDARY NSTALLATION required, contact your nearest ENVIRO dealer. EPLACING THE LASS The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see P .
  • Page 9: Maintaining Fascia And Surround Finishes

    Do not operate with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualified service person. The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed.
  • Page 10: Fuel Conversion

    Maintenance And Service ONVERSION TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 11 Maintenance And Service Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 8. b) Insert a c) Check that the screw is clean and if necessary Loosen Tighten d) Flip the screw (refer to Figure 10). e) Using the Allen wrench as shown in Figure 9, f) Verify that if the conversion is from NG to LPG, Figure 9: Removing valve...
  • Page 12: Initial Installation

    Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 13: Direct Vent Model

    Initial Installation QUALIFIED INSTALLERS ONLY IRECT ODEL WARNING: This appliance has been designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous situations. This model is vented with TWO (2) 3” aluminum or stainless steel flex vent leading into a co-linear to co- axial vent adaptor and using a Simpson Dura Vent vertical termination cap.
  • Page 14 Initial Installation Leveling legs bracket Figure 15: Installation of Leveling Legs. Surround Panel Figure 16: Corner brackets for trim. Figure 17: Two pieces of corner bracket. 6. Install the leveling legs. Thread the two (2) 5” (13 cm) bolts and locknut up into the captive nuts at each end of the leveling leg bracket (refer to Figure 15).
  • Page 15: Fan Controller & Burner Switch Installation

    Initial Installation QUALIFIED INSTALLERS ONLY 10. Connect the wires from the unit to the ON/OFF/ THERMOSTAT switch and the FAN CONTROLLER (see NITIAL NSTALLATION LECTRICAL 11. Place the assembled surround panel around the stove, align the slots. Push back then down to engage the surround panel hooks with the slots in the fireplace.
  • Page 16: Converting A Direct Vent Fireplace To A B-Vented Fireplace

    Initial Installation ONVERTING IRECT Parts required for conversion 1 - 300°F (149°C) manual reset spill switch and wires 1 - Drafthood (4’’ chimney connection) 2 - Air channels 1 - Drafthood diverter 1. Remove the chimney connector, fresh air cover plates and draft hood cover plate. 2.
  • Page 17: Venting Fireplace Inserts

    ENTING IREPLACE NSERTS The ENVIRO FOCUS may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed to ensure a tight seal, top performance, safety and efficiency.
  • Page 18: Electrical Requirements

    Initial Installation LECTRICAL EQUIREMENTS Figure 24: Focus Wiring Diagram. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Optional Remote Control 7 0 ° F Purple Grey Optional 7 0 °...
  • Page 19: Gas Line Connection

    Initial Installation QUALIFIED INSTALLERS ONLY ONNECTION Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. Gas Line Connection: •This fireplace is equipped with a certified flexible pipe located on the right side of the unit, terminating in a 3⁄8”...
  • Page 20: Secondary Installation

    Secondary Installation ET AND MBER NSTALLATION The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner comes with placement pins and rest areas, which make alignment easier.
  • Page 21: Brick Panel Installation

    Use of other foreign materials on the burners may create dangerous conditions. If over time, through cleaning and servicing, these embers require replacement , contact your nearest Enviro dealer. Figure 31: Focus Log Placement Complete. RICK...
  • Page 22: Trouble Shooting

    Trouble Shooting Problem Possible Cause The main burner The gas valve may not be on. does not ignite Thermostat is not calling for when called for. heat. Problem with gas valve. Spark will not Defective piezo ignitor. light the pilot after repeatedly Broken spark electrode.
  • Page 23: Parts List - Components

    Parts List - Components Reference Number Part Description 120°F (49°C) Ceramic Fan Temperature Sensor 300°F (149°C) Spill Switch Thermocouple Spark Electrode with Ignitor Cable Thermopile Fully Assembled Pilot NG Fully Assembled Pilot LP Pilot Orifice NG Threaded Pilot Orifice LP Threaded Pilot Gasket S.I.T.
  • Page 24 Parts List - Components Reference Number Part Description Door Only - Painted Venturi Owner’s Manual 3⁄8” NTP Male 3⁄8 Comp. 90° Elbow 1⁄4” NTP Female 3⁄8 Comp. 90° Elbow LP to NG Conversion Kit NG to LP Conversion Kit Conversion Kit BV to DV Conversion Kit DV to BV Extension Knob (Pilot) Extension Knob (HI-LO)
  • Page 25: Parts Diagram - Body

    Parts Diagram - Body...
  • Page 26: Parts List - Surrounds & Fascia

    Parts List - Surrounds & Fascia Reference Number Part Description Steel Bay Face - Polished Nickel Steel Bay Face With Glass - Painted Steel Bay Cover - Gold Steel Bay Cover - Polished Nickel Steel Bay Cover - Painted Steel Bay 3 Pieces Glass Set with Tape Standard Surround Panel - Black Trim Standard Surround Trim Only - Brass Standard Surround Trim Only - Black...
  • Page 27: Parts Diagram - Surrounds & Fascia

    Parts Diagram - Surrounds & Fascia...
  • Page 28: Parts List - Cast

    Parts List - Cast Reference Number Part Description Cast surround only - Painted Cast surround only - Antique White Cast surround only - Diamond Black Cast surround only - Inferno Red Cast surround only - Pearl Grey Cast surround only - Wedgewood Blue Cast surround only - Westport Green Cast surround only - Antique Chestnut Cast surround top piece.only - Painted...
  • Page 29 Parts List - Cast Reference Number Part Description Cast front only (no surround, glass, valve door, or clip) - Antique White Cast front only (no surround, glass, valve door, or clip) - Diamond Black Cast front only (no surround, glass, valve door, or clip) - Inferno Red Cast front only (no surround, glass, valve door, or clip) - Pearl Grey Cast front only (no surround, glass, valve door, or clip) - Wedgewood Blue 50-407 Cast front only (no surround, glass, valve door, or clip) - Westport Green...
  • Page 30: Parts Diagram- Cast Bay Front

    Parts Diagram- Cast Bay Front...
  • Page 31: Warranty

    Warranty Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime Warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location. Covered under the lifetime warranty are: the surround, the chassis and the heat exchanger.
  • Page 32: Installation Data Sheet

    Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ MODEL:___________________________________ SERIAL NUMBER:___________________________ DATE OF PURCHASE: _____________ DATE OF INSTALLATION:___________ � NATURAL GAS (NAT) INLET GAS PRESSURE:_________in wc MAIN BURNER ORIFICE:__________# DMS PILOT ORIFICE #_________OR________in diam.