3.1.2.5 Wash Motor/Pump Assembly
120VAC, 60Hz, 1.7A.
110W, MCR CS&R, 3250 rpm.
Class F
Capacitor 15µF 370V
WARNING: Motor is fitted with internal auto reset overload
and may restart without warning.
Resistance of windings @ 68°F ±5%
Brown & Blue - 6.9 ohms - Run
Blue & Black - 13.4 ohms - Start
Black & Brown - 20.3 ohms
3.1.3 Switches/thermostats
3.1.3.1 Thermostat - Overtemp
Identification - Green Dot.
Mounting - M4 x 0.7 male thread.
Electrical connection -1/4" Quick Connect terminals.
125V/250V.
Temperature specification: - Close 122°F ±10.
- Open 176°F ±6.
3.1.3.2 Thermostat - Boost
Identification - Black Dot.
Mounting - M4 x 0.7 male thread.
Electrical Connection - 1/4" Quick Connect terminals.
125V/250V
Temperature specification: - Open 117°F ±6.
- Close 136°F ±8.
3.1.3.3 Thermostat - Normal
Identification - Red Dot.
Mounting - M4 x 0.7 male thread.
Electrical connection -1/4" Quick Connect terminals.
125V/250V
Temperature specification: - Open 99°F ±6.
- Close 118°F ±8.
3.1.3.4 Microswitch - Undersump Overfill
250/125V, 10A, UL approved.
185°F maximum temperature.
Switch Mode - SPST.
Circuit - normally Open.
Silver CAD oxide contacts.
Electrical connection - 2 x 1/4" Quick Connect terminals.
3.1.3.5 Switch-Light
Models 5700 & 5900 only
240V/120VAC, 5A.
Circuit - normally Open.
Electrical connection - 2 x 1/4" Quick Connect terminals.
3.1.3.6 Switch - Fill System
125V/250VAC, 16A, UL approved.
Model 5600 only. Temperature - 248°F
Fixing/Mounting - snap in.
Contacts - silver.
Electrical connection - 1/4" silver plated brass Quick Con-
nect terminals.
Switch Mode - SPST
3.1.3.7 Microswitch - Door Lock
General Purpose Type approved by UL.
250/125VAC, 21A.
Pin Plunger Actuator SPST.
Normally open with common terminal at bottom.
Electrical connection - 1/4" Quick Connect terminals.
3.1.3.8 Pressure Switch - Mechanical
Main Contact Load - 16A, 240/125VAC.
Contacts- Nos. 1 & 3 utilized for heater.
- Nos. 1 & 2 utilized for drain.
Electrical connection
Nominal Calibration
Operating Temperature - 185°F maximum.
UL Approved.
3.1.3.9 Pressure Switch - Electronic
Main Contact Load - 1MA, 250/125VAC.
Electrical connection
Nominal Calibration
Operating Temperature - 185°F maximum.
NOTE: Contacts utilize No. 1 and No. 2 for empty condition.
Contact No. 3 is not utilized.
UL Approved.
9
- 1/4" Quick Connect terminals.
- set 2" water
- reset 19/32" water
- 1/4" Quick Connect terminals.
- set 2" water
- reset 19/32" water