Connecting The Drain Hose; Checking Drainage - Sharp AH-PN10 Operation Manual

Indoor/outdoor unit
Table of Contents

Advertisement

(1) Process the end of the connecting
cable for the indoor side.
(2) Open the open panel.
(3) Connect the cable.
(4) Fix the cable with the cable cover
and the short screw.
(5) Close the open panel.
Model 18000/24000 BTU
5 CABLE COVER
SHORT SCREW
CAUTIONS:
• Be very careful not to confuse the terminal connections. Wrong cabling may damage the internal
control circuit.
• Be sure to connect the cable to match the markings on the indoor unit's terminal board and those of
the outdoor unit.

CONNECTING THE DRAIN HOSE

Connecting the drain hose
(1) Connect a drain hose.
(2) Tape over the connecting part.
ø16 mm
Drain Hose (Commercially available)

Checking drainage

(1) Open the open panel.
(2) Remove the air filters.
(3) Pour some water into the drain pan.
(4) Check the water drains smoothly.
OM_AH-PN10 13GY_EN.indd Sec1:18
OM_AH-PN10 13GY_EN.indd Sec1:18
Model 9000/12000 BTU
5 CABLE COVER
SHORT SCREW
18K-Btu/h type
N
1
OUTDOOR UNIT
N
L
POWER SUPPLY
N
L
1
Cable
holder
Connect to
Power supply
outdoor
cable
NOTE:
• Be sure to lay the drain hose downward for smooth drainflow.
• Be careful not to allow the drain hose to rise, form a trap or
leave its end in water, as shown below.
• Coil thermal insulation around a drain hose extension, if run-
ning in the room.
E-18
Connecting
cable
24K-Btu/h type
N
L
OUTDOOR UNIT
N
L
POWER SUPPLY
N
L
Earth wire
Cable
holder
Connect to
outdoor
No trap
allowed.
Not running wavy.
Earth wire
Power supply
cable
1
1
Earth wire
Power supply
cable
Not to rise.
No trap allowed.
Not left
in water.
12/22/11 6:30:33 PM
12/22/11 6:30:33 PM