PIPES
Model
9K-Btu/h type
12K-Btu/h type
18K 24K-Btu/h type
• Standard piping length is 7.5m.
• When the outdoor unit is placed at a higher level than the indoor
unit, provide a trap near the hose's lead-in port.
Use the refrigerant pipes shown in the table below.
Pipe size
1/4" ( ø 6.35 mm)
Liquid side
9K-Btu/h type
Gas side
12K-Btu/h type
18K 24K-Btu/h type
• The thermal insulation should cover both the gas and liquid pipes.
INSTALLATION DIMENSION OF INDOOR UNIT
9000/12000 BTU
Center of
wall hole
18000/24000 BTU
88
I
E
E
OM_AH-PN10 13GY_EN.indd Sec1:15
OM_AH-PN10 13GY_EN.indd Sec1:15
Max. piping
Max. height
length:A
difference:B
10 m
5 m
15 m
7 m
15 m
10 m
3/8" ( ø 9.52 mm)
1/2" ( ø 12.7 mm)
5/8" ( ø 15.88 mm)
965 (Unit size)
860
175
Outline of indoor unit
I
I
F
115
F
965 (Unit size)
Outline of indoor unit
D
I
H
0
F
G
80
Center of wall hole
F
Min. piping
length
(piping length exceeds 7.5m)
1 m
Pipe
thickness
0.8 mm
1.0 mm
125
J
E
D
J
D
A
108
A
E
J
D
C
0
A
B
80
A
E-15
Additional refrigerant
15 g/m
10 g/m
A
B
B
Trap
Thermal insulation
Thickness: 6 mm or
thicker
Material: Polyethylene
foam
Length unit: mm
E
Center of wall hole
Length unit: mm
88
J
Center of wall hole
12/22/11 6:30:28 PM
12/22/11 6:30:28 PM