INSTALLATION MANUAL

SPLIT TYPE ROOM AIR CONDITIONER

SAFETY PRECAUTIONS

• Installation must be made in accordance with the installation manual by qualified service
personnel.
Incorrect work will cause electric shock, water leak, fire.
• Be sure to use the attached accessories parts and specified parts for installation.
Use of other parts will cause electric shock, water leak, fire, the unit falling.
• The appliance shall be installed in accordance with national wiring regulations.
Wrong connection can cause overheating or fire.
• After installation has complete, check that there is no leakage of refrigerant gas.
If the refrigerant gas contact with fire, it may generate toxic gas.
• Ventilate the room if refrigerant gas leakes during installation.
If the refrigerant gas contact with fire, it may generate toxic gas.
• Use the specified electrical cable.
Make sure the cable is secured in place and that the terminals are free of any excess force from
the cable.
Otherwise overheating or fire may result.
• Form the cable so that the control box cover, the cord holder and cable holder are not loose.
Otherwise overheating, fire or electric shock may result.
• Tighten the flare nut with a torque wrench according to the specified method.
If the flare nut is tightened too hard, the flare nut may be broken after a long time and cause
refrigerant gas leakage.
• When installing the unit, take care not to enter air substance other than the specified
refrigerant (R22) in the refrigerant cycle.
Otherwise, it will cause burst and injury as a result of abnormal high pressure in the refrigerant cycle.
• Be sure to connect the refrigerant pipe before running the compressor.
Otherwise, it will cause burst and injury as a result of abnormal high pressure in the refrigerant cycle.
• Earth the unit.
Incomplete earth may cause electrical shock.
• Install an earth leakage breaker to avoid electric shock in case of leak.
Use the current-activated, high-sensitivity, high-speed type breaker with a rated sensitivity current
of below 30 mA and an operating time of below 0.1 second.
• Arrange the drain hose to ensure smooth drainage.
Insufficient drainage may cause wetting of the room, furniture etc.
ACCESSORIES
ITEMS
1 MOUNTING PLATE
9K, 12K BTU
18K, 24K BTU
2 REMOTE CONTROL
OM_AH-PN10 13GY_EN.indd Sec1:13
OM_AH-PN10 13GY_EN.indd Sec1:13
Q'ty
ITEMS
3 DRY BATTERY
1
4 REMOTE CONTROL
HOLDER
1
E-13
Q'ty
ITEMS
5 CABLE COVER
9K, 12K BTU
2
18K, 24K BTU
6 OPERATION AND
INSTALLATION MANUAL
1
Q'ty
1
1
12/22/11 6:30:25 PM
12/22/11 6:30:25 PM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents