GCC Technologies Expert Pro Series User Manual page 33

Hide thumbs Also See for Expert Pro Series:
Table of Contents

Advertisement

Vacuum
To help improve tracking and cutting accuracy by turning on
the fans. If you turn off the vacuum system, the fans
will remain inactive during cutting or plotting.
Media Back
To enable to save time on repeated cutting jobs and better
& Forth
tracking.
After cutting job has finished, the media will move back to the
origin, then move to the end of the plot.
Paper Saving
To save media by four different modes:
Mode
1. Length expanded mode
3. Both expanded mode
Set
To build up the communication between host computer and
cutter.
Communication
Baud Rate is to determine the speed of data transmission.
Data Bits refers to the size of one block of data.
Parity is used to check if data was revived correctly or not.
9600, n, 7, 1, p
9600, o, 7, 1, p
9600, e, 7, 1, p
9600, n, 8, 1, p
9600, o, 8, 1, p
9600, e, 8, 1, p
19200, n, 7, 1, p
19200, o, 7, 1, p
19200, e, 7, 1, p
19200, n, 8, 1, p
19200, o, 8, 1, p
19200, e, 8, 1, p
Firmware
To display the version number of Firmware and FPGA code.
Version
Select
To select displayed languages on LCM panel in English,
Language
Spanish, Italian, Deutsch, Japanese, Portuguese, Polish,
Turkish or French.
Select Units
Provide two-unit systems for users convenient.
Scale Length
To adjust the scale of media length and width that may cause
by the thickness of the media.
The Denominator is the actual length, and the Numerator is
the ideal length measured from the resultant.
For example, cutting a line with 500.0 mm length. The
procedure as follows:
Scale Width
1. Press the [LEFT ARROW] to choose the Numerator and
select 500.0 mm,
2. Cut the length by sending a graph file,
3. Measure the length then use the [RIGHT ARROW] key to
choose the Denominator, then
4. Press [UP ARROW /DOWN ARROW] to change the
values of the actual length.
USB Printer
To select USB Mode from the LCM panel. Two USB modes
Type
are available: GCC USB Mode and Common USB Mode.
GCC USB Mode: Only for 32 bit driver
Common USB Mode: Both for 32 bit & 64 bit driver
The Control Panel
2. Width expanded mode
4. Both unexpanded mode
9600pbs, 7 Bits with NO Parity
9600pbs, 7 Bits with ODD Parity
9600pbs, 7 Bits with EVEN Parity
9600pbs, 8 Bits with NO Parity
9600pbs, 8 Bits with ODD Parity
9600pbs, 8 Bits with EVEN Parity
19200pbs, 7 Bits with NO Parity
19200pbs, 7 Bits with ODD Parity
19200pbs, 7 Bits with EVEN Parity
19200pbs, 8 Bits with NO Parity
19200pbs, 8 Bits with ODD Parity
19200pbs, 8 Bits with EVEN Parity
[Windows XP/2000/7/Vista]
[Windows XP/7/Vista]
3-6
Expert Pro User Manual
Enable
Disable
Both
unexpanded
mode
English
cm/gram;
Metric
inch/oz
Common
USB Mode

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents