DEBUG MODE-3
DSP DEBUG MODE(3/3)
Trouble Shooting by DSP DEBUG MODE (Continued)
Digit No.
Symptom on FL display
on FL
Continue to display "1"
10
Continue to display "2"
Continue to display "3" to "7"
Continue to display "8" to "F"
Displayed audio encoding
13
format is different from input
signal.
"x" is displayed
14
Continue to display "03"
-
15
20
Continue to display "05"
Continue to display "09" to
"10"
Continue to display "19"
Display "21" to "23",
then return and signal format
indicator is flashing.
Continue to display "24" to
"27", or "40" to "43".
Continue to display "29" to
"32"
This identifies IC which
27 28
outputs error
Cause of trouble
Interface between DSP and MPU is
no good.
Connection from DIR to DSP is no good.
Interface between DSP and MPU is
no good.
DSP Sequence is no good.
Input signal to DSP is no good.
a. No input signal to DSP.
b. Interface between DSP and MPU is
no good.
Communication between DSP and MPU
is no good.
Writing from MPU to DSP is no good.
DSP program does not run properly.
Flash ROM or SDRAM is no good.
The unit was powered off during DSP
firmware updating.
DSP program does not run properly.
Flash ROM or SDRAM is no good.
DSP program does not run properly.
Or audio clock to DSP is no good.
DSP setting is failured.
The IC outputs error to MPU.
TX-SR806/SA806
Remedy
The same remedy as
-b.
14
The same remedy as
.
13
The same remedy as
-b.
14
Check
-
items.
15
20
1. Confirm where the digital waveform stops
between DIR and DSP by oscilloscope.
2. Q3311, P1003 or P1005 may relate.
3. Resolder pins of the bad part or replace it with
new one.
The same as above.
1. Confirm where the digital waveform stops
between MPU and DSP by oscilloscope.
2. P1003, P1004 or P1005 may relate.
3. Resolder pins of the bad part or replace it with
new one.
1. The same remedy as
-b.
14
2. Check the voltage of the power supply pin of DSP.
3. Check the reset port and clock input of DSP by
oscilloscope, and find out bad part.
4. Flash ROM firmware is no good. Update.
5. DSP or MPU is broken. Replace MPU.
DSP is impossible to replace, so replace with
a new pcb.
1. Flash ROM firmware is no good, update.
2. Check DSPSDO pin of MPU by oscilloscope.
If no signal, find out bad part connected.
3. Flash ROM or SDRAM is no good, replace.
4. DSP or MPU is broken, replace the same method
as above 5.
1. Flash ROM firmware is no good, update.
2. Flash ROM or SDRAM is broken, replace.
Initialize the unit.
(Press ON/STANDBY button while pushing
VCR/DVR button when the unit is powered on.)
1. Flash ROM firmware is no good, upgrade.
2. Flash ROM or SDRAM is broken, replace.
1. Flash ROM program is no good, upgrade.
2. Flash ROM or SDRAM is broken, replace.
3. Check DSP drive clock freq. by oscilloscope.
If no signal, find out bad part connected.
4. Check audio clock to DSP by oscilloscope.
If no signal, find out bad part connected.
1. Flash ROM firmware is no good, upgrade.
2. Flash ROM or SDRAM is broken, replace.
Replace the IC chip.
DSP is impossible to replace, so replace with
a new pcb.