68
Spyder3 SG-34 GigE Vision Color Manual
Figure 50: Frame Trigger Source
In the Active Mod e grou p > set the Fram e Active Trigger Mod e valu e to ON .
Figure 51: Frame Trigger Mode: On
Note on the Frame Active Trigger
When the fram e trigger goes high, the PC w ill collect d ata u ntil either, the signal goes low , or the fram e bu ffer
is filled . The fram e height length w ill be d eterm ined by the length of the fram e trigger .
At this point you can enable fram e d elayer as w ell.
Figure 52: Frame Active Delay
03-032-20124-00
Teledyne DALSA