Note on the Frame Start Trigger
When the fram e trigger goes high the softw are grabs a pred efined nu m ber of lines , as d efined in w id th and
height in Im age Form at Control.
For a softw are trigger toggle Fram e softw are trigger from a False valu e to a Tru e valu e, or from Tru e to False
d epend ing on the Fram e Active Trigger Mod e.
Enable the d elayer in the Start Mod e grou p > set the Fram e Start Delay valu e to Tru e.
Figure 47: Frame Start Delay
In the Fram e Trigger Fu nction Grou p > set the Fram e Trigger Delayer valu e.
Figure 48: Frame Trigger Delayer
External Frame Trigger – Frame Active Trigger mode.
In the Start Mod e grou p > Make su re Fram e Start Trigger Mod e is Off.
Figure 49: Frame Start Trigger Mode: Off
In the Fram e Trigger Fu nction Grou p > Set the Device Scan type to Areascan.