Spyder3 SG-34 GigE Vision Color Manual
External Frame Trigger: Frame Start Trigger mode
In the Fram e Trigger Fu nction Grou p > set the Device Scan Type to Linescan.
Figure 44: Device Scan Type
In the Active Mod e grou p > ensu re that the Fram e Active Trigger Mod e valu e is Off.
Figure 45: Frame Trigger Mode
In the Start Mod e grou p > set the Fram e Start Trigger Mod e valu e to ON .
Figure 46: Frame Start Trigger Mode