Dalsa Spyder3 SG-34-04k80-00-R User Manual page 63

Spyder3 gige vision bilinear color line scan camera
Hide thumbs Also See for Spyder3 SG-34-04k80-00-R:
Table of Contents

Advertisement

Spyder3 SG-34 GigE Vision Color Manual
63
If the rescaler is need ed , set the rescaler as show n in the follow ing figu re:
Figure 37: Rescaler
If the rescaler is enabled , the external line frequ ency w ill be m od ified u sing the Trigger Mu ltiplier and Trigger
Divid er com m and s, as show n above. For d etails, please refer to the Rescaler section in the GURU section.
N ote: the Trigger Mu ltiplier takes the follow ing three valu es only:
0 = frequ ency x 256
1 = frequ ency x 16
2 = frequ ency x 4096
For m ore inform ation abou t the Rescaler, please refer to Rescaler in the GURU section.
External Line Trigger, External Direction Control from Rotary
Encoder
Physically connect rotary Encod er phase A to pin1-5 if u sing TTL, or pin 1-2 if u sing LVDS, and phase B to pin
6-5 if u sing TTL, or pin6-7 if u sing LVDS.
In the Line Trigger Fu nction Grou p > Set the Line Trigger Mod e valu e to On.
Set Rotary Encod er Mod u le to Tru e.
Figure 38: Rotary Encoder Module