Electrical Connection - FireplaceXtrordinair 4237 EG Installation Manual

Hide thumbs Also See for 4237 EG:
Table of Contents

Advertisement

20

Electrical Connection

The electrical line must be connected to the wires inside the junction box (hot, common, and 2 ground
wires) by a qualified installer or electrician and must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical lines.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The electrical line must be a min. 14 gauge, and supply 120 Volts, 60 Hz (typical max amps: 5).
Route the electrical connection through the ZC cover plate and junction box cover plate and attach to
the hookup wires pictured below.
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
© Travis Industries
Installation
9/22/2021 - 1561
(for qualified installers only)
4237 EG

Advertisement

Table of Contents
loading

Table of Contents