  • Page 1 User Guide For Xerox SAFEStor Storage Enclosure R e v is io n 1 .0 Ja n u a ry 2 0 06...
  • Page 2: Table Of Contents

    Table of Contents Chapter 1 – Introduction ..........................1 F e a tu r e s a n d B e n e f its ..........................1 Configurations ............................1 Understanding RAID............................2 RAID 0..............................2 RAID 1..............................2 RAID 0+1.............................
  • Page 3 Delete Pass Through........................28 Identify Drive ..........................29 S y s te m C o n tr o ls..........................30 System Configuration........................30 U320 SCSI Target Configuration ....................31 EtherNet Config ..........................31 Alert By Mail Configuration ......................32 SNMP Configuration........................34 NTP Configuration ........................
  • Page 4 Terminal Port Config........................61 Update Firmware ........................... 62 Restart Controller .......................... 63 U 3 2 0 S C S I T a r g e t C o n f ig ........................63 E th e r n e t C o n f ig u r a tio n ........................64 DHCP Function ..........................
  • Page 5 • XRX-2PSQX-652-FC A ud ienc e This User Guide is intended for use by the person installing and/or operating the Xerox XRX series storage enclosure. For details about the host system, refer to the documentation supplied with the host system C on ven tio ns U se d In T his U ser G uid e The following conventions are used throughout this User Guide.
  • Page 6: Chapter 1 - Introduction

    If you are unfamiliar with these operations, please consult your computers User Guide. Featu res and B enefits The Xerox SAFEStor RAID Series offers an extremely versatile and low cost solution, perfect for any End-User environment where high performance, problem free mass storage is required, including: •...
  • Page 7: Understanding Raid

    SAFEStor User Guide U nd ersta n din g R A ID RAID is an acronym for Redundant Array of Independent Disks. A RAID system consists of an array of multiple independent hard disk drives that provide high performance and fault tolerance.
  • Page 8: Raid 0+1

    SAFEStor User Guide RAID 0+1 RAID 0+1 is a combination of RAID 0 and RAID 1, combining stripping with disk mirroring. RAID Level 0+1 combines the fast performance of Level 0 with the data redundancy of Level 1. In this configuration, data is distributed across several disk drives, similar to Level 0, which are then duplicated to another set of drives for data protection.
  • Page 9: Raid 5

    SAFEStor User Guide RAID 5 In RAID 5, the parity information is written to all of the drives in the array rather than being concentrated on a dedicated parity disk. If one drive in the array fails, the parity information can be used to reconstruct the missing data from that drive.
  • Page 10: Chapter 2 - Initial Setup And Installation

    SAFEStor User Guide Chapter 2 – Initial Setup and Installation This Chapter describes the installation and set up of the SAFEStor storage enclosure. Important safety details are described along with the environmental and electrical precautions that must be taken. The location of components within the enclosure is also shown.
  • Page 11: Air Flow

    ‘clicks’ into place. Lo catin g C o m p on ents The SAFEStor family uses dual external 180W power supplies which plug into the rear of the unit. The following pictures show where the components are located within the enclosures.
  • Page 12: Rear View Of The Unit

    SAFEStor User Guide The above drawing shows the front view of SAFEStor with the door opened. Behind the door are the 6 hot swappable drive caddies. Rear View of the unit . The rear connector points of the SCSI unit are show in the following diagram.
  • Page 13: Raid Controller

    SAFEStor User Guide RAID Controller To gain access to the RAID controller it is necessary to remove the backplate assembly. The RAID controller is mounted horizontally above the drive bays and is attached to the rear panel. To remove the controller follow the steps outlined below: 1.
  • Page 14: Drive Carrier

    SAFEStor User Guide 4. Remove the four securing screws and remove the assembly 5. Detach the controller from the assembly by removing the four mounting screws. Drive Carrier The drives are mounted in purpose designed caddies. The caddies are designed for hot swap operation with a damping handle and EMI shielding.
  • Page 15 SAFEStor User Guide Drive Mounting Screws The drives are mounted from the underside of the drive caddy by the four screws shown in the diagram above. Page 10...
  • Page 16: Chapter 3 - Initial Configuration

    SAFEStor User Guide Chapter 3 – Initial Configuration This Chapter describes how to install the hardware and how to connect to and access the RAID Controller. Attaching the SCSI Cables to XRX-2PSQX-651-U4 There are two SCSI ports on the rear of the XRX-2PSQX-651-U4 enclosure. Attach the SCSI cable (or 2 cables if required) to the SCSI ports.
  • Page 17: W Eb Brow Ser-Based R A Id M An Ager

    SAFEStor User Guide Connection Null-modem cable Baud Rate 115,200 Data bits Stop Flow Control None By connecting a VT100 terminal, or a PC operating in an equivalent terminal emulation mode, all RAID subsystem monitoring, configuration and administration functions can be carried out.
  • Page 18: W Eb Brow Ser-Based R A Id M An Ager Via H T T P P Roxy

    SAFEStor User Guide W eb brow ser-based R A ID m an ager via H T T P P roxy The browser based RAID manager can be accessed via a HTTP Proxy. The RAID System comes with proxy software for Windows based host systems.
  • Page 19: Configuration Menu Tree

    SAFEStor User Guide Configuration Menu Tree The following diagram details the menu structure of the RAID manager, which can be accessed via the RS-232 serial port and Ethernet LAN port. NOTE: Alert by Email Configuration can only be set in the web-based configuration Front Panel Operation The system can also be configured from the front panel display.
  • Page 20 SAFEStor User Guide The four buttons are designated: Enter – Selects a menu option Esc – Backs up a level ↓ - Moves forward to next field ↑ - Moves backward to next field The button correspondence is as follows: The default password is “0000”...
  • Page 21: Chapter 4 - Configuration Using Web Module

    SAFEStor User Guide Chapter 4 – Configuration Using Web Module The RAID Controller of the Storage Enclosure can be configured and managed using the Web based RAID management software. This chapter describes how to use the Web based software. For information on accessing the Web based RAID Management Software refer to Chapter 3.
  • Page 22: R A Id S Et F Unctions

    SAFEStor User Guide This screen contains the following fields: Total Number of Disks The total number of disk drives that are available for the RAID Volume set. Select RAID Level Select the RAID level to be applied to the RAID Volume...
  • Page 23: Delete Raid Set

    SAFEStor User Guide From the navigation panel, select Create RAID Set. In the information panel, the list of the disk drives available for inclusion in the RAID set is displayed. Use the check boxes to select the drives to be included in the RAID Set and then check the Confirm The Operation check box and click Submit.
  • Page 24: Expand Raid Set

    SAFEStor User Guide Expand RAID Set This function allows you to expand a RAID Set by adding one or more disk drives to it. This means that you do not have to delete an existing RAID Set and recreate it with more drives.
  • Page 25: Create Hot Spare

    SAFEStor User Guide Using the check boxes, select the RAID Sets to be activated, then click Submit, to make the RAID Sets active. Create Hot Spare This function allows you to create a Hot Spare drive. The hot spare drive will always be ready to instantly be used in the event of a disk drive failing in a RAID Set.
  • Page 26: Rescue Raid Set

    SAFEStor User Guide Using the check boxes, select the hot spare drive to be deleted, then check the Confirm The Operation check box and then click Submit. Confirm the deletion, and the hot spare is deleted. Rescue RAID Set This function allows you to rebuild a RAID set if it has gone off-line. To rescue the RAID set, follow the procedure below: From the navigation panel, click Rescue RAID Set.
  • Page 27: V Olu M E Set F Un Ctions

    SAFEStor User Guide In the Enter The Keyword text box, type the keyword as required (see 1 above), then check the Confirm The Operation check box and then click Submit. V olu m e Set F un ctions This section describes the Volume Set functions of the RAID Management software. These functions allow you to create, delete, modify and check a Volume.
  • Page 28 SAFEStor User Guide This screen has the following attributes that must be assigned: Member Disks Displays the number of disks in the RAID set that the Volume Set is being created from. Volume RAID Level Select the RAID Level to apply to the Volume Set from the drop down list.
  • Page 29: Delete Volume Set

    SAFEStor User Guide When all the above attributes have been assigned, check the Confirm The Operation check box then click Submit. The Volume Set is created. NOTE: This operation may take some time depending on the RAID type selected and the size of the Volume Set.
  • Page 30: Check Volume Set

    SAFEStor User Guide Using the check boxes, select the Volume Set that you wish to modify then click Submit. The attributes for the selected Volume Set are displayed. This screen has the following attributes that can be modified: Volume Name...
  • Page 31: Stop Volume Set Check

    SAFEStor User Guide This function allows you to verify the correctness of the redundant data in a volume set. For example, in a system with dedicated parity, volume set check means computing the parity of the data disk drives and comparing the results to the contents of the dedicated parity disk drive.
  • Page 32: Modify Pass Through

    SAFEStor User Guide Using the check boxes, select the disks that you want to assign as a pass through disk. Assign the attributes to the pass through drive by specifying the following information: Volume Cache Mode Select the Cache Mode to be applied to the Pass Through Drive using the drop down list.
  • Page 33: Delete Pass Through

    SAFEStor User Guide following attributes can be modified on this screen: Change the Cache Mode to be applied to the Pass Through Drive Volume Cache Mode using the drop down list. Tagged Command Queuing Change whether to enable or disable tagged command queuing using the drop down list.
  • Page 34: Identify Drive

    SAFEStor User Guide Using the check boxes, select the Pass Through Drive you wish to delete. Check the Confirm The Operation check box and then click Submit to delete the Pass Through Drive. Identify Drive This function allows you to see where a disk drive is physically located within the storage enclosure by making the drives LED flash on the front of the enclosure.
  • Page 35: System C Ontrols

    SAFEStor User Guide System C ontrols This section describes the System Controls functions of the RAID Management Software. These functions allow you to configure alarms, notifications and passwords, as well as upgrading controller firmware and restarting the controller. System Configuration This function allows you to set system wide parameters.
  • Page 36: U320 Scsi Target Configuration

    SAFEStor User Guide can support from the drop down list. HDD Read Ahead Sets the drives to read in more data than requested Cache in anticipation of a subsequent request for the data Stagger Power On This setting allows the drives to spin up in 0.5 second Control increments (from 1 second onwards).
  • Page 37: Alert By Mail Configuration

    SAFEStor User Guide The following parameters can be set from this screen: DHCP Function Select whether you want to enable or disable DHCP functionality on the enclosure using the drop down list. Local IP Address Enter the local IP address in the boxes (if...
  • Page 38 SAFEStor User Guide The following parameters can be set from this screen: SMTP Server IP Enter the IP address of the SMTP server to be used for email Address notifications. Sender Name Enter a name that will displayed to the person receiving the email alert.
  • Page 39: Snmp Configuration

    SAFEStor User Guide Once all the parameters have been set, check the Confirm The Operation check box and then click Submit to configure email notification. SNMP Configuration This function allows you to configure SNMP settings for the RAID Controller. To configure the SNMP settings, follow the procedure below: From the navigation panel, select SNMP Configuration.
  • Page 40: Ntp Configuration

    SAFEStor User Guide Once the above information has been added, check the Confirm The Operation check box and then click Submit to set the SNMP Configuration parameters. NTP Configuration Use this screen to input the parameters of the Network Time Protocol (NTP) server to use for time synchronization.
  • Page 41: Generate Test Event

    SAFEStor User Guide This screen shows the date and time that the events took place, the device that the event was generated from and the type of the event etc. Generate Test Event This function allows you to generate a test event. This is used to ensure that your event notification process is working correctly.
  • Page 42: Upgrade Firmware

    SAFEStor User Guide From the navigation panel, select Modify Password. The Modify Password screen is displayed in the information panel. Enter the original password and then enter the new password twice. Check the Confirm The Operation check box and then click Submit.
  • Page 43: Inform Ation

    SAFEStor User Guide To restart the controller, check the Confirm The Operation check box and then click Submit. Inform ation These functions allow you to view general information relating to the RAID sets, system and hardware. RAID Set Hierarchy This function allows you to view general information relating to the RAID sets created on the system.
  • Page 44: System Information

    SAFEStor User Guide its hyperlinked name. System Information This function displays detailed information about the RAID Controller. To view the detailed information, select System Information from the navigation panel. The system information is displayed in the information panel. Hardware Monitor This function allows you to view hardware information relating to the storage enclosure.
  • Page 45 SAFEStor User Guide Page 40...
  • Page 46: Chapter 5 - Configuration Using Vt100

    SAFEStor User Guide Chapter 5 – Configuration Using VT100 This chapter describes how to configure the RAID Controller using a VT100 terminal emulation program. For details on how to access the VT100 menus, refer to Chapter 3. K eyb oard N avig atio n The following key–functions are used to navigate through the VT-100 RAID configuration...
  • Page 47: Q Uick V Olum E/R Aid Setup

    SAFEStor User Guide Q uick V olum e/R aid Setup Quick Volume/Raid Set-up is the fastest way to prepare a raid set and volume set. It can be completed with just a few keystrokes. Although drives of different capacity may be used in the raid set, the smallest capacity drive in the RAID set is used as the capacity of all disk drives in the RAID set.
  • Page 48: R Aid S Et F Unction

    SAFEStor User Guide Press Yes in the Create Vol/Raid Set dialog box, the raid set and volume set will start to initialize. R aid S et F unction RAID Sets can be configured manually from the RAID Set Function menu. From this function you can manually create, delete, expand and activate a raid set.
  • Page 49: Delete Raid Set

    SAFEStor User Guide The Edit The Raid Set Name option appears. Enter a name for the RAID Set by entering 1 to 15 alphanumeric characters. The default raid set name is Raid Set #. Delete Raid Set To delete a RAID set, select the raid set number you want to delete from the Select Raid Set to Delete option.
  • Page 50: Activate Incomplete Raid Set

    SAFEStor User Guide To expand a raid set, follow the procedure below: Click Expand Raid Set. If there are available disks, the Select Drives For Raid Set Expansion menu appears. Select the Raid Set and then select the disk. A confirmation screen appears. Select Yes to confirm.
  • Page 51: Delete Hot Spare

    SAFEStor User Guide Scroll to the required disk using the arrow keys. Press Enter to select a disk. Select Yes in “Create Hot Spare?” to designate the drive as a hot spare. Delete Hot Spare This option allows you to delete a hot spare drive.
  • Page 52: V Olu M E Set F Un Ction

    SAFEStor User Guide Raid Set Name Shows the name of the Raid Set Member Disks Shows the number of disks belonging to the Raid Set. RAID State Shows the status of the Raid Set. Total Capacity Shows the total capacity available in the Raid Set.
  • Page 53 SAFEStor User Guide The Volume Creation option is displayed showing the current settings for the volume set. The Volume Creation option allows you to select the Volume Name, RAID level, Capacity, Stripe Size, SCSI or FC ID/LUN, Cache Mode, Tag Queuing and Max Sync Rate.
  • Page 54 SAFEStor User Guide Each volume set can have a capacity which is less than, or equal to, the total capacity of the raid set on which it resides. Stripe Size This parameter sets the size of the segment written to each disk in a RAID 0, 1, 0+1, 5 or 6 logical drive.
  • Page 55: Delete Volume Set

    SAFEStor User Guide Repeat steps 3 to 5 to create additional volume sets. The initialization progress is displayed at the bottom of the screen. Delete Volume Set To delete a Volume set, select the Delete Volume Set option by pressing Enter. The list of all available RAID sets is displayed.
  • Page 56 SAFEStor User Guide To change a Volume set attribute, scroll to the attribute and press Enter. Make the modification and then press ESC to save the change. The following attributes can be modified: Volume Name The default volume name will always appear as Volume Set.
  • Page 57: Check Volume Set

    SAFEStor User Guide Max Sync Rate The RAID subsystem supports 320 MB/sec as the highest data transfer rate for the Ultra 320 SCSI system. Check Volume Set Use this option to verify the correctness of the redundant data in a volume set. For...
  • Page 58: View Drive Information

    SAFEStor User Guide View Drive Information This option allows you to view details about the physical disks in the RAID subsystem. Selecting the View Drive Information option displays a list of all disk drives attached to the controller. Scroll to the desired drive and press Enter. The following information about the...
  • Page 59: Modify Pass-Through Disk

    SAFEStor User Guide Scroll to a disk drive and press Enter to set the attributes for the Pass Through Drive. Scroll to the attribute you wish to edit and press Enter. Edit the attribute and then press ESC to save the change and return to the previous menu.
  • Page 60: Delete Pass-Through Disk

    SAFEStor User Guide Select the parameter from the list you which to change, press Enter to modify it, then press ESC to save the change and return to the previous menu. Delete Pass-Through Disk To delete a Pass-through drive select Delete Pass-Through Drive, then press Enter. A list of all Pass Through Drives is displayed.
  • Page 61: R A Id S Ystem F U Nction

    SAFEStor User Guide R A ID S ystem F u nction The Raid System Function menu allows you to manage the RAID controller. Mute The Alert Beeper The Mute The Alert Beeper function allows you to control the RAID subsystem Beeper.
  • Page 62: Alert Beeper Setting

    SAFEStor User Guide Alert Beeper Setting The Alert Beeper function allows you to Disable or Enable the RAID subsystem controller beeper. Select Disabled and press Enter to turn the beeper off. Or, select Enable and press Enter to turn the beeper on.
  • Page 63: Raid/Jbod Function

    SAFEStor User Guide screen. The RAID subsystem will automatically go back to the initial screen when it does not receive any command for twenty seconds. To disable the password, press Enter (without entering any alphanumeric characters) in both the Enter New Password and the Re-Enter New Password column. The existing password will be cleared.
  • Page 64: Maximum Sata Mode

    SAFEStor User Guide Maximum SATA Mode The Maximum SATA Mode function allows you to set the maximum SATA mode that the system can support as well as enabling Native Command Queuing (NCQ). Select the Max SATA mode from the list and press Enter to select.
  • Page 65: Stagger Power On

    For example a two second interval ensures that commands are issued to individual drives every two seconds. The setting for SAFEStor products should be set to a minimum of 2.5 seconds. HDD SMART Status Polling This features allows the controller to take advantage of monitoring SMART information from the disk drives.
  • Page 66: Capacity Truncation

    SAFEStor User Guide Capacity Truncation The Capacity Truncation function allows you to select how the disk capacity is to be truncated. For example, if you select , all disk capacities will be rounded M ultip le s o f 1 0 G down to the nearest 10G i.e.
  • Page 67: Update Firmware

    SAFEStor User Guide The Terminal Port Config function allows you to configure the terminal port. From this screen you can set the Baud Rate and the Stop Bits values. Press Enter to select Baud Rate or Stop Bit and edit the settings. Press ESC to save the change and return to the previous menu.
  • Page 68: Restart Controller

    SAFEStor User Guide Restart Controller This function allows you to restart the controller. Select Restart Controller from the menu and press Enter. The Restart Controller confirmation screen appears. Select Yes to restart the RAID controller. NOTE: Ensure that there is no Host and Drive activity before restarting the controller.
  • Page 69: E Thern Et C On Figuration

    SAFEStor User Guide E thern et C on figuration These functions allow you to set the controller Ethernet port configuration. You do not need to create a reserved space on the arrays before the Ethernet port and HTTP service will function.
  • Page 70: Http Port Number

    SAFEStor User Guide Http Port Number This function allows you to set the port number to be used as the HTTP port for the RAID controller. Select HTTP Port Number and press Enter. Type a new port number and then press ESC to save the new Port Number and return to the previous menu.
  • Page 71: Hardw Are Monitor

    SAFEStor User Guide H ard w are M onitor The Hardware Monitor Information provides the temperature, of any drives present within the enclosure. It also provides the temperature, fan speed (chassis fan) and the voltage of the RAID subsystem. All items are read-only. The warning messages will be indicated through the Fault LED’s or the alarm buzzer.
  • Page 72: System Inform Ation

    SAFEStor User Guide System Inform ation Choose this option to display details of the Main processor, CPU Instruction cache and data cache size, firmware version, serial number, controller model name, and the cache memory size. To view the system information, select System Information and then press Enter.