3.5
Empty Battery
3.5.1 KDC100/200/250/300/350
The KDC will display the message Empty Battery Connect USB when the battery is empty. Please
charge the KDC IMMEDIATELY to prevent data collecting interruption.
3.5.2 KDC400
Under 30% - Orange LED flickers at 1-second-interval for 5 seconds every minute.
Under 20% - Orange LED flickers in 1- second-interval for 10 seconds every minute.
Under 10% - Red LED flickers in 1- second-interval for 10 seconds every minute and
you will hear beeping sound.
3.6
Buffer Full
The KDC will display the message Buffer Full when the size of collected data reaches160KB (85
version)/60KB(86 version) or the number of collected barcodes is 10,240. To prevent the loss of
data, you should synchronize the data then reset the memory when this message displays.
4MB version KDC reaches Buffer Full condition as follows:
0.5MB Partition - Collected data size reaches 0.5MB or collected number is 25,600
1MB Partition - Collected data size reaches 1MB or collected number is 51,200
2MB Partition - Collected data size reaches 2MB or collected number is 102,400
3MB Partition - Collected data size reaches 3MB or collected number is 153,600
4MB Partition - Collected data size reaches 4MB or collected number is 204,800
3.7
Reset Feature
The Reset feature lets you restart the KDC if necessary without losing any stored barcode data
or option settings. To reset the KDC, follow these steps.
Press DOWN scroll button and SCAN button simultaneously for 5 seconds.
1.
When the LEDs illuminate yellow, release the buttons.
2.
The KDC initial screen, KoamTac Data Collector KDC displays when reset is complete.
3.
Note:
The KDC stores collected data into flash memory and will not lose data or the
KDC settings during the reset process.
66
Revision 3.05.R6
Copyright ® 2013, KoamTac, Inc.
KDC User Manual