E62: Overheating During Washing - Electrolux EWM1100 Service Manual

Front-loading washing machine
Table of Contents

Advertisement

E62
The temperature of the NTC sensor exceeds 88°C for more than 5 minutes
Tests to be performed:
Start the diagnostic cycle
and fill with water up to the
level of the door to ensure
that the heating element is
completely dipped into.
Measure between wiring
connector J2-2 and the
structure of the appliance -
see fig 6 -
Is the circuit open?
YES
Measure the NTC sensor
across terminals J9-9 and
J9-8 of the circuit board
connector.
Is the value correct?
(between 5.7 and 6.3 KΩ at
20°C)
YES
Replace the circuit board
and restart the diagnostic
cycle to check for further
alarm conditions.
2007-10 SOI/DT-mdm FCPD-dp Quality-fz

E62: Overheating during washing

Detach the connector and
NO
measure across the heating
element and the ground
Is the circuit open?
Check/replace the wiring and restart the diagnostic cycle to check
Detach the connector and
NO
measure directly on the
Is the value correct?
(between 5.7 and 6.3 KΩ at
Check/replace the wiring
and restart the diagnostic
cycle to check for further
alarm conditions.
fig. 14
contact.
- see fig. 15 -
YES
for further alarm conditions.
NTC sensor.
- see fig. 14 -
20°C)
YES
Circuit
board
43/59
Replace the heating
NO
element and restart the
diagnostic cycle to check
for further alarm
conditions.
Replace the NTC sensor
NO
and restart the diagnostic
cycle to check for further
alarm conditions.
If there are traces of burning
on the circuit board, refer to
page
E62
fig. 15
59
fig. 6
599 70 32-47

Hide quick links: