E35
The electronic board measures a water level from analogic pressure switch
Tests to be performed:
Empty the machine.
Are pressure switch hose and air trap
system free? (You can disconnect the
hose and blow in it to check if the system
is free) -see fig. 2 and 8-
YES
Is the machine
filling water when
main switch is
turned OFF?
YES
Replace the inlet
valves and
repeat
completely the
diagnostic cycle
to check for
further alarm
conditions.
2007-10 SOI/DT-mdm FCPD-dp Quality-fz

E35: Water level too high

higher then 300 mm for more then 15 seconds.
Get inside
diagnostic cycle
at
step
8. After
door lock is the
NO
machine also
filling water?
YES
Replace the main
board and repeat
completely the
diagnostic cycle
to check for
further alarm
conditions.
fig. 8
Clean/change the hoses and/or air trap
system and repeat completely the
NO
diagnostic cycle to check for further
Is the cable
between main
board and
analogic pressure
NO
switch connected
correctly on both
sides?
YES
Replace the
analogic
pressure switch
and run the
diagnostic cycle
to check for
further alarm
conditions.
If there are traces of burning on the
27/59
alarm conditions.
Reconnect
and/or replace
the cable and do
the diagnostic
NO
cycle completely
again to check
for further alarm
conditions.
circuit board, refer to page
599 70 32-47
E35
59