E62
The temperature of the NTC probe exceeds 88C for more than 5 mins.
Checks to perform:
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
(see fig 6)
Is the circuit open?
Y
E
S
Measure the NTC probe
between terminals J3-4 and
J3-5 of the main circuit
board connector.
Is the value correct?
(between 5.7 and 6.3K at
20°C)
Y
E
S
Replace the circuit board
and repeat the diagnostic
cycle to check for any
further alarms.
Fig. 6
Fig. 18
Fig. 19
2013 TS/DT-mdm FCPD-dp
Guide to diagnostics of EWX11831 electronic controls

E62: Overheating during washing

Detach the connector and
measure between the
heating element and the
NO
earth contact.
- (see fig. 19)-
Is the circuit open?
Check/replace the wiring and repeat the diagnostic cycle to check
Detach the connector and
measure the value directly
on the NTC probe.
NO
- (see fig. 18)-
Is the value correct?
(between 5.7 and 6.3K at
Check/replace the wiring and repeat the diagnostic cycle to check
Washing heating
element
5.7 ÷ 6.3K
(20°C)
!
Check that all the connectors are correctly inserted
NO
Y
E
S
for any further alarms.
NO
20°C)
Y
E
S
for any further alarms.
If there are burns on the circuit board,
!
50/71
E62
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
5.7 ÷ 6.3K
(20°C)
MAIN CIRCUIT
BOARD
see page 69
599 77 00-82 Rev. 01