The analogic pressure switch is giving an error during the calibration
E32
(At the beginning of each cycle the appliance drain to empty the tub
and create a 0 level to verify the calibration of the analogic pressure switch)
Tests to be performed:
Drain the water from the tub.
Are pressure switch hose and air trap
system free? (You can disconnect the
hose and blow in it to check if the
system is free) fig. 2 and 8
YES
Check the draining system (filter,
drain pump, drain hose). Is the
machine draining correctly?
YES
Select a washing cycle. After few
minutes did the machine fill with water
and the motor is turning?
YES
Appliance is OK.
2007-10 SOI/DT-mdm FCPD-dp Quality-fz
phase
Clean/change the hoses and/or air trap
system and repeat completely the
diagnostic cycle to check for further
NO
Clean the draining system.
NO
Replace the analogic pressure switch
and run again the diagnostic cycle to
check for further alarm conditions.
NO
Fig.2
26/59
alarm conditions.
YES
If there are traces of burning on the
circuit board, refer to page
E32
59
fig. 8
599 70 32-47