Procedure For Checking The Commutator Motors - Electrolux EWM1100 Service Manual

Front-loading washing machine
Table of Contents

Advertisement

1) Check the connector blocks (wiring)
and check for detached or bent
terminals.
2) Check for traces, residue or deposits
of water or detergent on the motor and
identify the source.
3) Check for windings or other parts that
may be grounded or poorly insulated.
Use a tester with a minimum scale of
40 MΩ: between each terminal and the
casing, this should read ∞ (fig. 10).
4) Check each winding against the values
shown in the table below (fig. 11).
TERMINALS
ON MOTOR
TERMINAL BLOCK
A
6-7
B
2-5
C
3-4
D
1-5
N.B.: When checking the rotor winding, the measurement must be effected over the entire surface, rotating
the spindle very slowly and checking for short-circuits between visible plates. Also check the brushes for
wear.
2007-10 SOI/DT-mdm FCPD-dp Quality-fz

Procedure for checking the commutator motors

CHECKS:
Winding of tachymetric
generator
Stator winding (full
range)
Rotor winding
(overheating breaker)
Stator winding
(half range, presence of
terminal 1)
fig. 10
P = motor protector
R = rotor S = stator
T = tachometric generator
C.E.SET.
ACC
[ ]
(FHP)
63÷74
125÷145
1.0÷2.0
0.9÷3.2
1.6÷2.7
0.5÷3.0
0.34÷0.65
0.4÷1.2
fig. 11
39/59
MOTORS
ACC
BSH
ECM
(SOLE)
468÷540
14÷16
84÷98
171÷197
0.8÷1.9
1.4÷1.9
1.3÷1.6
1.4÷2.3
1.5÷1.9
1.8÷2.5
0.4÷1.0
1.0÷1.2
0.6÷0.8
599 70 32-47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents