Eh1: Incorrect Mains Frequency; Eh2: Mains Voltage Too High; Eh3: Mains Voltage Too Low - Electrolux EWM1100 Service Manual

Front-loading washing machine
Table of Contents

Advertisement

EH1
Tests to be performed:
Important!
The appliance remains in alarm mode until the frequency returns to the correct value or the appliance is
switched off (programme selector on "0"). Only the family of the alarm is displayed, and the diagnostic
cycle cannot be started. The complete alarm can be read only when the alarm condition has ceased.
Is there interference in the power line, or is the
mains frequency outside the correct limits?
Have the user check and if necessary repair
the domestic power supply circuit.
EH2
Mains voltage higher than configured voltage (for more than 10 seconds)
Tests to be performed:
Important!
The appliance remains in alarm mode until the frequency returns to the correct value or the appliance is
switched off (programme selector on "0"). Only the family of the alarm is displayed, and the diagnostic
cycle cannot be started. The complete alarm can be read only when the alarm condition has ceased.
Is there interference in the power line, or is the
mains voltage outside the correct limits?
Have the user check and if necessary repair
the domestic power supply circuit
EH3
Tests to be performed:
Important!
The appliance remains in alarm mode until the frequency returns to the correct value or the appliance is
switched off (programme selector on "0"). Only the family of the alarm is displayed, and the diagnostic
cycle cannot be started. The complete alarm can be read only when the alarm condition has ceased.
Is there interference in the power line, or is the
mains voltage outside the correct limits?
Have the user check and if necessary repair
the domestic power supply circuit.
2007-10 SOI/DT-mdm FCPD-dp Quality-fz

EH1: Incorrect mains frequency

The power supply frequency is not within the configured limits
YES

EH2: Mains voltage too high

YES

EH3: Mains voltage too low

Mains voltage lower than configured voltage
YES
NO
Replace the circuit board and restart the
diagnostic cycle to check for further alarm
NO
Replace the circuit board and restart the
diagnostic cycle to check for further alarm
NO
Replace the circuit board and restart the
diagnostic cycle to check for further alarm
If there are traces of burning on the
circuit board, refer to page
54/59
conditions.
conditions.
conditions.
599 70 32-47
EH1
EH2
EH3
59