PENSOTTI PCH 18 Instruction Manual page 32

Wall mounted heat only boiler premix condensing system boiler
Table of Contents

Advertisement

To enter the parameters menu, follow the previously described procedure (steps 1-5).
00
S
P 01
S
01
S
P 02
S
01
S
P 03
S
REGULATION INSTRUCTIONS
P
ARAMETER
6. Use buttons „+‟ and „-„ to modify the value of the
110V 60Hz
7. Press and release button „S‟ to confirm. The parameter
110V 60Hz
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
P
ARAMETER
6. Use buttons „+‟ and „-„ to modify the value of the
110V 60Hz
7. Press and release button „S‟ to confirm. The parameter
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
110V 60Hz
P
ARAMETER
110V 60Hz
6. Use buttons „+‟ and „-„ to modify the value of the
7. Press and release button „S‟ to confirm. The parameter
8. Switch off the appliance and switch it back on again to
110V 60Hz
render the new parameter operative.
1 – T
YPE OF BOILER
parameter:
00 = Instantaneous boiler
01 = Storage boiler;
02 = Storage boiler „comfort‟ (+45°F);
03 = D.H.W. Temperature setting 95-160 °F
number (1) will appear on the display.
2 - G
AS SUPPLY
parameter:
00 = natural gas
01 = lpg
number (2) will appear on the display.
3 – C
ENTRAL HEATING TEMPERATURE
parameter:
00 = standard (86 – 176°F)
01 = reduced (77 – 104 °F) for under-floor heating
number (3) will appear on the display.