Flue Connections - PENSOTTI PCH 18 Instruction Manual

Wall mounted heat only boiler premix condensing system boiler
Table of Contents

Advertisement

3.9 Flue connections

In order to ensure that the appliance functions correctly
and efficiently, the flue connection between the boiler
and the flue terminal must be made using original
components
specifically
boilers.
Traditional
flue
conveying exhaust fumes from condensing boilers, nor
vice versa.
● In order to make the choice of which flue to install easier, in
addition to being drawn differently, the above-mentioned system
is also differentiated in the flue catalogue and general price list
by the insertion of the words "...in polypropylene..." .
● It is recommended that:
o
for the exhaust discharge duct, the entire length of the flue
slopes upwards towards the exterior in order to facilitate the
flow of condensate back to the combustion chamber, which
has been specifically designed to collect and drain the acidic
condensate;
o
for the air intake, the entire length of the duct slopes upwards
towards the boiler to prevent the entry of rainwater, dust or
foreign bodies into the pipe;
o
in case of a vertical flue pipe installation, a condensate trap is
fitted at the base of the flue installation and connected into
drainage system (see fig. 1);
● In the case where a horizontal coaxial system is installed, the
coaxial terminal must be positioned horizontally in that the
exhaust duct has been specifically designed with the required
slope and the air intake has been suitably protected against the
weather
;
Concentric Flue connections
It is mandatory that the manufacturers venting system be used.
Use only materials listed below for vent pipe and fittings. Failure to
comply could result in personal injury, death or property damage and could void the boiler warranty.
Installations must comply with local code requirements and with U.S. ANSI Z223.1.
All venting must be properly supported. Boilers are not intended to support any type of vent system.
All vent pipe joints must be secured using ½‟‟ galvanized screws.
Item
PAHVK
PAHVKD
Deluxe 3/5" Vent Kit, includes Termination, Wall sleeve, 90° Ell, 10" Conc. Pipe, 39" Conc. Pipe & 2/4-3/5 Adapter w/ Test ports
PA27058LA
PA27059LA
PA27088LA
PA27089LA
PA43186LA
PA80020LA
PA82112LP
PA82118LA
PA82254LA
INSTALLATION INSTRUCTIONS
designed
for
components
cannot
Standard 3/5" Vent Kit, includes Termination, 90° Ell, Wall sleeve and 2/4 to 3/5 adapter
Pensotti Flat Roof Outlet Flashing
Pensotti 45 Degree Co-Axial Elbow 3/5"
Pensotti 90 Degree Co-Axial Elbow 3/5"
Pensotti Horizontal Conc. Flue Terminal 3/5"
Pensotti Vertical Conc. Flue Terminal 3/5"
condensing
be
used
for
Fig. 1
Fig. 2
Description
Pensotti Pitched Roof Flashing
Pensotti 5" Rubber Wall Plate
Pensotti 39" Conc. Pipe 3/5"
Pensotti. 10" Conc. Pipe 3/5"
20
FLUE DUCT
YES