3. Using a 15/16" open end wrench, disconnect
the manifold pipe from the valve.
4. Remove the (1) screw securing the gas valve
assembly bracket to the base, slide the gas valve
assembly forward and lift the gas valve assembly
out.
5. Remove the (2) screws holding the valve to the
bracket.
Removing the gas valve coils (Gas dryer):
1. Disconnect the dryer from electrical supply and
remove the front panel.
2. Disconnect the wires from the coils, remove the
(2) screws holding the coil bracket to the valve
base and lift the coils off.
Removing the sensor (Gas dryer):
1. Disconnect the dryer from electrical supply and
remove the front panel.
2. Disconnect the (2) wires from the sensor.
3. Remove the (1) screw holding the sensor to the
combustion chamber.
Removing the combustion chamber
(Gas dryer):
1. Disconnect the dryer from electrical supply,
remove the sensor and gas valve assembly.