Removing the heating element assembly
(Electric dryer):
1. Disconnect the dryer from electrical supply and
remove the drum.
2. Disconnect the (2) wires from the heating element.
3. Remove the high limit thermostat.
4. From the rear of the dryer, remove the (4) screws
securing the heating element assembly to the rear
of the cabinet.
Removing the control thermistor:
1. Disconnect the dryer from electrical supply and
remove the front panel.
2. Disconnect the wires from the thermistor and re-
move the (2) screws holding the thermistor to the
blower housing.
Removing the blower housing and fan
blade:
1. Disconnect the dryer from electrical supply and
remove the drum.
2. Remove the control thermistor.
3. Using a 7/8" socket, turn the fan blade clockwise
while holding the motor shaft to remove the blade
from the motor shaft.